{"id":68708,"date":"2025-06-10T13:12:00","date_gmt":"2025-06-10T11:12:00","guid":{"rendered":"https:\/\/fhi.nl\/nieuws\/introducing-the-ea-bim-20005-battery-impedance-meter-delivering-accuracy-and-industry-leading-throughput\/"},"modified":"2025-06-10T13:18:28","modified_gmt":"2025-06-10T11:18:28","slug":"introducing-the-ea-bim-20005-battery-impedance-meter-delivering-accuracy-and-industry-leading-throughput","status":"publish","type":"news","link":"https:\/\/fhi.nl\/en\/news\/introducing-the-ea-bim-20005-battery-impedance-meter-delivering-accuracy-and-industry-leading-throughput\/","title":{"rendered":"Introducing the EA-BIM 20005 Battery Impedance Meter, Delivering Accuracy and Industry-Leading Throughput"},"content":{"rendered":"<header id=\"header\" class=\"header header--high header--branch\">\n\n\t\t\t\t\t\t\t\t\t\t<div class=\"header__background header__background--high\">\n\t\t\t\t\t<img decoding=\"async\" class=\"header__background-image\" src=\"https:\/\/fhi.nl\/app\/uploads\/2025\/06\/tektronix_ea-eim-20005_front_on_022.jpg\" alt=\"\">\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\n\t\n\t<div class=\"container\">\n\t\t<div class=\"header__content\">\n\t\t\t<div class=\"header__first\">\n\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<h1 class=\"header__title\" >\n\t\t\t\t\tIntroducing the EA-BIM 20005 Battery Impedance Meter, Delivering Accuracy and Industry-Leading Throughput\t\t\t\t<\/h1>\n\n\t\t\t\t<div class=\"header__dots-line\">\n\t\t\t\t\t<svg width=\"431\" height=\"9\" viewbox=\"0 0 431 9\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M430.799 4.192a1.136 1.136 0 1 1-2.272-.001 1.136 1.136 0 0 1 2.272 0Zm-27.272 0a1.135 1.135 0 1 1-2.27 0 1.135 1.135 0 0 1 2.27 0Zm-27.27 0a1.136 1.136 0 1 1-2.272-.001 1.136 1.136 0 0 1 2.272 0Zm-27.272 0a1.39 1.39 0 1 1-2.78 0 1.39 1.39 0 0 1 2.78 0Zm-27.78 0a1.645 1.645 0 1 1-3.29 0 1.645 1.645 0 0 1 3.29 0Zm-28.29 0a1.9 1.9 0 1 1-3.799 0 1.9 1.9 0 0 1 3.799 0Zm-28.799 0a2.154 2.154 0 1 1-4.308 0 2.154 2.154 0 0 1 4.308 0Zm-29.308 0a2.41 2.41 0 1 1-4.819 0 2.41 2.41 0 0 1 4.819 0Zm-29.819 0a2.663 2.663 0 1 1-5.326.001 2.663 2.663 0 0 1 5.326-.001Zm-30.327 0a2.919 2.919 0 1 1-5.837 0 2.919 2.919 0 0 1 5.837 0Zm-30.837 0a3.173 3.173 0 1 1-6.345.001 3.173 3.173 0 0 1 6.345 0Zm-31.346 0a3.428 3.428 0 1 1-6.856 0 3.428 3.428 0 0 1 6.856 0Zm-31.856 0a3.683 3.683 0 1 1-7.365 0 3.683 3.683 0 0 1 7.365 0Zm-32.365 0a3.937 3.937 0 1 1-7.875 0 3.937 3.937 0 0 1 7.875 0Zm-32.874 0a4.192 4.192 0 1 1-8.384 0 4.192 4.192 0 0 1 8.384 0Z\" fill=\"#FFF960\"\/><\/svg>\t\t\t\t<\/div>\n\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div>\n\n\t\t\t\t\t\t\t<div class=\"header__second\">\n\n\t\t\t\t\t\n\t\t\t\t\t\n\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t\t\t<div class=\"header__branch-logos\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/fhi.nl\/app\/uploads\/2024\/02\/Industriele-elektronica.svg\" class=\"header__branch-logo\" alt=\"\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\n\t\t\t\t\t\n\t\t\t\t\t\n\t\t\t\t<\/div>\n\t\t\t\n\t\t<\/div>\n\t<\/div>\n<\/header>\n\n\t<div class=\"header__meta\">\n\t<div class=\"container\">\n\t\t<div class=\"header__meta__category\">\n\n\t\t\t\t\t\t\t<div class=\"header__meta__detail\">\n\t\t\t\t\t<div>Branch<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/fhi.nl\/en\/kennishub\/?_branches_kennishub=industriele-elektronica\" class=\"header__meta__detail--branch\">\n\t\t\t\t\t\t\t\tIndustrial Electronics\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t<div class=\"header__meta__detail\">\n\t\t\t\t\t<div>Subject<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/fhi.nl\/en\/kennishub\/?_onderwerp_kennishub=industriele-elektronica\" class=\"header__meta__detail--categorie\">\n\t\t\t\t\t\t\t\tIndustrial Electronics\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/fhi.nl\/en\/kennishub\/?_onderwerp_kennishub=test-en-meetapparatuur\" class=\"header__meta__detail--categorie\">\n\t\t\t\t\t\t\t\tTest and measuring equipment\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\n\t\t<\/div>\n\t<\/div>\n<\/div>\n\n<div class=\"text bg--white\">\n\t<div class=\"container\">\n\t\t\t\t\t\t\t\t\t\t\t<div class=\"text__content text__content--1-col\">\n\t\t\t<div class=\"inner-block text\">\r\n<p>Today, evaluating batteries got better, faster. The new EA-BIM 20005 battery impedance meter delivers industry-leading throughput, performing electrochemical impedance spectroscopy (EIS) measurements across up to 20 channels. Designed for seamless integration, it features industry-standard interfaces and a compact design, empowering engineers to enhance accuracy and efficiency in battery testing workflows.<\/p>\r\n<p>As battery technology rapidly evolves, ensuring the quality and reliability of Li-Ion battery cells remains paramount. Battery impedance testing using EIS provides deep insight into cell quality. Validation and quality assurance engineers operate under intense time pressure, balancing the need for measurement accuracy, high throughput, and battery impedance testing across wide frequency ranges, various states of charge, and thermal conditions. Identifying the right instrument is just the first step\u2014seamless integration into existing workflows is crucial to maintaining performance and productivity. The EA-BIM 20005 meets these challenges head-on, setting a new standard for battery testing efficiency.<\/p>\r\n<p>Starting today, the new EA-BIM 20005 Battery Impedance Meter is available for purchase.<\/p>\r\n<p>\u00a0<\/p>\r\n<h3>Get Deeper Insight and Reproducible Test Results<\/h3>\r\n<p>The EA-BIM 20005-10-20 model offers broad-frequency EIS capabilities, with a frequency range from 1 mHz to 10 kHz. This wide range provides significantly more information than fixed 1 kHz systems, allowing for a comprehensive analysis of battery cell behavior under various conditions. The system&#039;s AC stimulus can reach up to 10A (peak-peak), making it suitable for testing cylindrical, pouch, and prismatic cells.<\/p>\r\n<p>Every EIS channel in the EA-BIM 20005 is accompanied by a high-precision 4-wire PT100 temperature measurement channel. This integration allows for simultaneous tracking of impedance and cell temperature, providing a more holistic view of battery performance and health.<\/p>\r\n<p>The EA-BIM 20005 is designed to work seamlessly with cycle testing systems. Its integrated power stage enables the charging and discharging of cells with a current of +\/- 1A. For higher currents it can also be used in concert with high-power battery test systems such as the EA-BCTS. Additionally, the system can always remain connected, recognizing the influences of cabling and power stages of battery testers, thus eliminating the need to disconnect\/reconnect cables for each test.<\/p>\r\n<p><img decoding=\"async\" class=\"alignnone wp-image-5620 size-full\" src=\"https:\/\/cnrood.com\/wp-content\/uploads\/2025\/06\/impedance-measurement.webp\" alt=\"\" width=\"650\" height=\"433\" \/><\/p>\r\n<p><em>Figure 1. A conventional swept impedance measurement can take 300 seconds, while an advanced multi-frequency technology measurement can take just 1 second.<\/em><\/p>\r\n<p><em>\u00a0<\/em><\/p>\r\n<h3>The Fastest EIS Measurement System in the Industry<\/h3>\r\n<p>The EA-BIM 20005 is equipped with advanced multi-sine stimulus technology, enabling impedance measurements at multiple frequencies simultaneously. This innovation makes the system hundreds of times faster than traditional sweep methods. It can also perform sweep measurements, offering flexibility in testing approaches. With the ability to test up to 20 channels with fast multiplexing, the EA-BIM 20005 sets a new standard for throughput in battery testing.<\/p>\r\n<p><img decoding=\"async\" class=\"alignnone wp-image-5619 size-full\" src=\"https:\/\/cnrood.com\/wp-content\/uploads\/2025\/06\/bim-software-screen-800.webp\" alt=\"\" width=\"640\" height=\"427\" \/><\/p>\r\n<p><em>Figure 2. Included PC software makes it easy to configure tests and analysis results. The meter connects to the PC via USB.<\/em><\/p>\r\n<p>\u00a0<\/p>\r\n<h3>Easily Integrate High-Throughput EIS into Your Battery Test Workflow<\/h3>\r\n<p>The EA-BIM 20005 comes with Included PC software, which simplifies the battery impedance testing process. Users can configure settings effortlessly, evaluate measurements with built-in visualizations and analysis tools, and record results in their preferred file formats. The software supports both standard sweep measurements and rapid multi-sine measurements, catering to various testing requirements. It also allows for measurements under dynamic operating conditions, such as superimposed charging and discharging currents.<\/p>\r\n<p>The EA-BIM 20005 features industry-standard interfaces, including a USB device port for PC connection and a CAN Bus for integration into battery cycle automation systems. These interfaces ensure easy integration into custom test programming and existing testing workflows.<\/p>\r\n<p>With 20 EIS measurement channels in a compact 3U design, the EA-BIM 20005 boasts outstanding channel density, preserving valuable bench and floor space in your testing environment. In addition, its low power consumption (&lt;60W) eliminates the need for active cooling,<\/p>\r\n<p>\u00a0<\/p>\r\n<h3>Conclusion<\/h3>\r\n<p>The EA-BIM 20005 battery impedance meter is a game-changer for electrical validation engineers, quality assurance engineers, and systems engineers. By providing fast, accurate insights into Li-Ion battery cell quality through high-throughput battery impedance testing, this system enhances the efficiency and reliability of battery testing workflows. Its broad-frequency EIS capabilities, integrated temperature measurement, seamless cycle testing integration, advanced multi-sine stimulus technology, and user-friendly software make it an indispensable tool for modern battery impedance testing. With industry-standard interfaces and a compact, energy-efficient design, the EA-BIM 20005 is poised to set a new benchmark in battery impedance measurement.<\/p>\r\n<\/div>\r\n<div class=\"inner-block buttons\"><a class=\"button blue\" href=\"https:\/\/cnrood.com\/wp-content\/uploads\/2025\/06\/EA-BIM-20005_Datasheet_1EW741620.pdf\" target=\"\"> Download Datasheet <\/a> <a class=\"button blue\" href=\"https:\/\/cnrood.com\/contact\/\" target=\"\">\u00a0<\/a><\/div>\r\n<div class=\"inner-block buttons\"><a class=\"button blue\" href=\"https:\/\/cnrood.com\/contact\/\" target=\"\">Contact CN Red <\/a><\/div>\t\t<\/div>\n\t<\/div>\n<\/div>\r\n\t<div class=\"articles bg--offwhite automatic\">\r\n\t\t<div class=\"container\">\r\n\t\t\t<div class=\"articles__header\">\r\n\t\t\t\t\t\t\t\t\t<div class='heading-wrapper'><svg width=\"13\" height=\"13\" viewbox=\"0 0 13 13\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><circle cx=\"6.394\" cy=\"6.5\" r=\"6.394\" fill=\"#000\"\/><\/svg><h2>Related articles<\/h2><\/div>\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"\/en\/profiel\/cnrood\/\" class=\"button button--outline\">view profile<\/a>\r\n\t\t\t\t\t\t\t<\/div>\r\n\t\t\t\t\t\t<div class=\"post-grid post-grid--no-padding\">\r\n\t\t\t\t\n<a class=\"single-item single-item__articles\" href=\"https:\/\/fhi.nl\/en\/news\/pt-node-network-adapter-for-printing-and-data-transfer\/\" data-id=\"34545\">\n\t<div class=\"single-item__articles-icon\">\n\t\t<svg width=\"82\" height=\"98\" viewbox=\"0 0 82 98\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\">\n<path fill-rule=\"evenodd\" clip-rule=\"evenodd\" d=\"M26.5586 7.96501C26.5586 6.61879 26.8909 5.49682 27.3233 4.77796C27.7792 4.02009 28.1318 4 28.1466 4H55.0564C55.0712 4 55.4238 4.02009 55.8796 4.77796C56.312 5.49682 56.6444 6.61879 56.6444 7.96501C56.6444 9.31122 56.312 10.4332 55.8796 11.1521C55.4238 11.9099 55.0712 11.93 55.0564 11.93H54.2487C53.8841 11.5449 53.3681 11.3047 52.796 11.3047H28.981C28.5233 11.3047 28.1015 11.4584 27.7644 11.7171C27.6381 11.602 27.4874 11.4248 27.3233 11.1521C26.8909 10.4332 26.5586 9.31122 26.5586 7.96501ZM26.981 15.7683C25.6024 15.3755 24.5619 14.3215 23.8956 13.2138C23.0294 11.7738 22.5586 9.91326 22.5586 7.96501C22.5586 6.01675 23.0294 4.15622 23.8956 2.71619C24.7383 1.31517 26.1797 0 28.1466 0H55.0564C57.0232 0 58.4646 1.31517 59.3073 2.71619C60.1735 4.15622 60.6444 6.01675 60.6444 7.96501C60.6444 9.91326 60.1735 11.7738 59.3073 13.2138C58.4646 14.6148 57.0232 15.93 55.0564 15.93H54.796V40.3243L80.5327 84.0062L80.5391 84.0172L80.5503 84.0368C84.0711 90.2609 79.5954 97.9997 72.4362 97.9997H9.34052C2.18152 97.9997 -2.29415 90.2608 1.22665 84.0368C1.23243 84.0265 1.23831 84.0163 1.24428 84.0062L26.981 40.3243V15.7683ZM30.981 15.93V35.792H39.161C40.2655 35.792 41.161 36.6874 41.161 37.792C41.161 38.8966 40.2655 39.792 39.161 39.792H30.981V40.8697C30.981 41.2268 30.8854 41.5773 30.7041 41.8849L21.3184 57.8149H60.4585L51.0728 41.8849C50.8916 41.5773 50.796 41.2268 50.796 40.8697V15.93H30.981ZM62.8152 61.8148C62.8065 61.8149 62.7978 61.8149 62.7891 61.8149H19.4727C19.3082 61.8149 19.1484 61.7951 18.9954 61.7577L4.70016 86.0205C2.69212 89.5942 5.27194 93.9997 9.34052 93.9997H72.4362C76.5051 93.9997 79.0848 89.5941 77.0768 86.0205L62.8152 61.8148Z\" fill=\"#FFDA56\"\/>\n<\/svg>\n\t<\/div>\n\t<div class=\"single-item__articles-title\"><div class='heading-wrapper'><h3>PT-Node Network Adapter for Printing and Data Transfer<\/h3><\/div><\/div>\n\t<div class=\"single-item__articles-terms\">\n\t\t\n\t\t\n\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">Laboratory Technology<\/span>\n\t\t\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">LabNL<\/span>\n\t\t\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">General laboratory equipment<\/span>\n\t\t\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">Food &amp; Beverage<\/span>\n\t\t\t\t\t<\/div>\n\t<div class=\"single-item__articles-author-date-wrapper\">\n\t\t\t\t\t<div class=\"single-item__articles-author\">\n\t\t\t\tProlyse BV\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"single-item__articles-date\">\n\t\t\t\tSeptember 25, 2024\t\t\t<\/div>\n\t\t\t<\/div>\n<\/a>\n\n<a class=\"single-item single-item__articles\" href=\"https:\/\/fhi.nl\/en\/news\/keysight-expands-ecommerce-offering-adds-new-software-bundles\/\" data-id=\"38396\">\n\t<div class=\"single-item__articles-icon\">\n\t\t<svg width=\"35\" height=\"35\" viewbox=\"0 0 35 35\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\">\n<mask id=\"mask0_1182_5532\" style=\"mask-type:luminance\" maskunits=\"userSpaceOnUse\" x=\"0\" y=\"0\" width=\"35\" height=\"35\">\n<path d=\"M0 0H35V35H0V0Z\" fill=\"white\"\/>\n<\/mask>\n<g mask=\"url(#mask0_1182_5532)\">\n<path d=\"M5.12695 9.22852H1.02539V31.9238H10.4299C12.2868 31.9238 14.0678 32.6615 15.3809 33.9746H19.6191C20.9322 32.6615 22.7132 31.9238 24.5701 31.9238H33.9746V11.2793H29.873\" stroke=\"#2A5CEE\" stroke-width=\"2\" stroke-miterlimit=\"10\"\/>\n<path d=\"M17.5 9.22852H18.1426C20.0088 7.89544 22.2237 7.17773 24.5615 7.17773H29.873V27.8223H24.5615C22.2237 27.8223 20.0088 28.54 18.1426 29.873H16.8574C14.9912 28.54 12.7763 27.8223 10.4385 27.8223H5.12695V5.12695H9.22852\" stroke=\"#2A5CEE\" stroke-width=\"2\" stroke-miterlimit=\"10\"\/>\n<path d=\"M9.22852 1.02539V21.6699C13.759 21.6699 17.5 25.3425 17.5 29.873V9.22852C17.5 4.698 13.759 1.02539 9.22852 1.02539Z\" stroke=\"#2A5CEE\" stroke-width=\"2\" stroke-miterlimit=\"10\"\/>\n<\/g>\n<\/svg>\n\t<\/div>\n\t<div class=\"single-item__articles-title\"><div class='heading-wrapper'><h3>Keysight Expands eCommerce Offering; Adds New Software Bundles<\/h3><\/div><\/div>\n\t<div class=\"single-item__articles-terms\">\n\t\t\n\t\t\n\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">Members content<\/span>\n\t\t\t\t\t<\/div>\n\t<div class=\"single-item__articles-author-date-wrapper\">\n\t\t\t\t\t<div class=\"single-item__articles-author\">\n\t\t\t\tKeysight Technologies Netherlands BV\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"single-item__articles-date\">\n\t\t\t\tJuly 21, 2021\t\t\t<\/div>\n\t\t\t<\/div>\n<\/a>\n\t\t\t<\/div>\r\n\t\t<\/div>\r\n\t<\/div>","protected":false},"excerpt":{"rendered":"<p>The EA-BIM 20005 battery impedance meter is a game-changer for electrical validation engineers, quality assurance engineers, and systems engineers. By providing fast, accurate insights into Li-Ion battery cell quality through high-throughput battery impedance testing, this system enhances the efficiency and reliability of battery testing workflows. Its broad-frequency EIS capabilities, integrated temperature measurement, seamless cycle testing integration, advanced multi-sine stimulus technology, and user-friendly software make it an indispensable tool for modern battery impedance testing.<\/p>","protected":false},"featured_media":68709,"template":"","branches":[13],"events":[361,9,364,365,60,8],"secretariat":[42],"categories":[57,22],"themes_tax":[509],"content_types":[514],"class_list":["post-68708","news","type-news","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Introducing the EA-BIM 20005 Battery Impedance Meter, Delivering Accuracy and Industry-Leading Throughput<\/title>\n<meta name=\"description\" content=\"By providing fast, accurate insights into Li-Ion battery cell quality through high-throughput battery impedance testing, this system enhances the efficiency and reliability of battery testing workflows.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cnrood.com\/news\/introducing-the-ea-bim-20005-battery-impedance-meter\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Introducing the EA-BIM 20005 Battery Impedance Meter, Delivering Accuracy and Industry-Leading Throughput\" \/>\n<meta property=\"og:description\" content=\"By providing fast, accurate insights into Li-Ion battery cell quality through high-throughput battery impedance testing, this system enhances the efficiency and reliability of battery testing workflows.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cnrood.com\/news\/introducing-the-ea-bim-20005-battery-impedance-meter\/\" \/>\n<meta property=\"og:site_name\" content=\"FHI, federatie van technologiebranches\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-10T11:18:28+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/fhi.nl\/app\/uploads\/2025\/06\/tektronix_ea-eim-20005_front_on_022.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"750\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/fhi.nl\\\/nieuws\\\/introducing-the-ea-bim-20005-battery-impedance-meter-delivering-accuracy-and-industry-leading-throughput\\\/\",\"url\":\"https:\\\/\\\/cnrood.com\\\/news\\\/introducing-the-ea-bim-20005-battery-impedance-meter\\\/\",\"name\":\"Introducing the EA-BIM 20005 Battery Impedance Meter, Delivering Accuracy and Industry-Leading Throughput\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/fhi.nl\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/cnrood.com\\\/news\\\/introducing-the-ea-bim-20005-battery-impedance-meter\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/cnrood.com\\\/news\\\/introducing-the-ea-bim-20005-battery-impedance-meter\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/fhi.nl\\\/app\\\/uploads\\\/2025\\\/06\\\/tektronix_ea-eim-20005_front_on_022.jpg\",\"datePublished\":\"2025-06-10T11:12:00+00:00\",\"dateModified\":\"2025-06-10T11:18:28+00:00\",\"description\":\"By providing fast, accurate insights into Li-Ion battery cell quality through high-throughput battery impedance testing, this system enhances the efficiency and reliability of battery testing workflows.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/cnrood.com\\\/news\\\/introducing-the-ea-bim-20005-battery-impedance-meter\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/cnrood.com\\\/news\\\/introducing-the-ea-bim-20005-battery-impedance-meter\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/cnrood.com\\\/news\\\/introducing-the-ea-bim-20005-battery-impedance-meter\\\/#primaryimage\",\"url\":\"https:\\\/\\\/fhi.nl\\\/app\\\/uploads\\\/2025\\\/06\\\/tektronix_ea-eim-20005_front_on_022.jpg\",\"contentUrl\":\"https:\\\/\\\/fhi.nl\\\/app\\\/uploads\\\/2025\\\/06\\\/tektronix_ea-eim-20005_front_on_022.jpg\",\"width\":750,\"height\":500},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/cnrood.com\\\/news\\\/introducing-the-ea-bim-20005-battery-impedance-meter\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/fhi.nl\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Nieuws\",\"item\":\"https:\\\/\\\/fhi.nl\\\/nieuws\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Introducing the EA-BIM 20005 Battery Impedance Meter, Delivering Accuracy and Industry-Leading Throughput\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/fhi.nl\\\/#website\",\"url\":\"https:\\\/\\\/fhi.nl\\\/\",\"name\":\"FHI, federatie van technologiebranches\",\"description\":\"Nederlandse branchevereniging voor technologiebranches\",\"publisher\":{\"@id\":\"https:\\\/\\\/fhi.nl\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/fhi.nl\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/fhi.nl\\\/#organization\",\"name\":\"FHI, federatie van technologiebranches\",\"url\":\"https:\\\/\\\/fhi.nl\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/fhi.nl\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/fhi.nl\\\/app\\\/uploads\\\/2024\\\/06\\\/3-e1722349014385.png\",\"contentUrl\":\"https:\\\/\\\/fhi.nl\\\/app\\\/uploads\\\/2024\\\/06\\\/3-e1722349014385.png\",\"width\":732,\"height\":136,\"caption\":\"FHI, federatie van technologiebranches\"},\"image\":{\"@id\":\"https:\\\/\\\/fhi.nl\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/fhi-federation-of-technology-branches\",\"https:\\\/\\\/www.instagram.com\\\/fhi_nl\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Introducing the EA-BIM 20005 Battery Impedance Meter, Delivering Accuracy and Industry-Leading Throughput","description":"By providing fast, accurate insights into Li-Ion battery cell quality through high-throughput battery impedance testing, this system enhances the efficiency and reliability of battery testing workflows.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cnrood.com\/news\/introducing-the-ea-bim-20005-battery-impedance-meter\/","og_locale":"en_GB","og_type":"article","og_title":"Introducing the EA-BIM 20005 Battery Impedance Meter, Delivering Accuracy and Industry-Leading Throughput","og_description":"By providing fast, accurate insights into Li-Ion battery cell quality through high-throughput battery impedance testing, this system enhances the efficiency and reliability of battery testing workflows.","og_url":"https:\/\/cnrood.com\/news\/introducing-the-ea-bim-20005-battery-impedance-meter\/","og_site_name":"FHI, federatie van technologiebranches","article_modified_time":"2025-06-10T11:18:28+00:00","og_image":[{"width":750,"height":500,"url":"https:\/\/fhi.nl\/app\/uploads\/2025\/06\/tektronix_ea-eim-20005_front_on_022.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/fhi.nl\/nieuws\/introducing-the-ea-bim-20005-battery-impedance-meter-delivering-accuracy-and-industry-leading-throughput\/","url":"https:\/\/cnrood.com\/news\/introducing-the-ea-bim-20005-battery-impedance-meter\/","name":"Introducing the EA-BIM 20005 Battery Impedance Meter, Delivering Accuracy and Industry-Leading Throughput","isPartOf":{"@id":"https:\/\/fhi.nl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/cnrood.com\/news\/introducing-the-ea-bim-20005-battery-impedance-meter\/#primaryimage"},"image":{"@id":"https:\/\/cnrood.com\/news\/introducing-the-ea-bim-20005-battery-impedance-meter\/#primaryimage"},"thumbnailUrl":"https:\/\/fhi.nl\/app\/uploads\/2025\/06\/tektronix_ea-eim-20005_front_on_022.jpg","datePublished":"2025-06-10T11:12:00+00:00","dateModified":"2025-06-10T11:18:28+00:00","description":"By providing fast, accurate insights into Li-Ion battery cell quality through high-throughput battery impedance testing, this system enhances the efficiency and reliability of battery testing workflows.","breadcrumb":{"@id":"https:\/\/cnrood.com\/news\/introducing-the-ea-bim-20005-battery-impedance-meter\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cnrood.com\/news\/introducing-the-ea-bim-20005-battery-impedance-meter\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/cnrood.com\/news\/introducing-the-ea-bim-20005-battery-impedance-meter\/#primaryimage","url":"https:\/\/fhi.nl\/app\/uploads\/2025\/06\/tektronix_ea-eim-20005_front_on_022.jpg","contentUrl":"https:\/\/fhi.nl\/app\/uploads\/2025\/06\/tektronix_ea-eim-20005_front_on_022.jpg","width":750,"height":500},{"@type":"BreadcrumbList","@id":"https:\/\/cnrood.com\/news\/introducing-the-ea-bim-20005-battery-impedance-meter\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/fhi.nl\/"},{"@type":"ListItem","position":2,"name":"Nieuws","item":"https:\/\/fhi.nl\/nieuws\/"},{"@type":"ListItem","position":3,"name":"Introducing the EA-BIM 20005 Battery Impedance Meter, Delivering Accuracy and Industry-Leading Throughput"}]},{"@type":"WebSite","@id":"https:\/\/fhi.nl\/#website","url":"https:\/\/fhi.nl\/","name":"FHI, federation of technology industries","description":"Dutch trade association for technology industries","publisher":{"@id":"https:\/\/fhi.nl\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/fhi.nl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/fhi.nl\/#organization","name":"FHI, federation of technology industries","url":"https:\/\/fhi.nl\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/fhi.nl\/#\/schema\/logo\/image\/","url":"https:\/\/fhi.nl\/app\/uploads\/2024\/06\/3-e1722349014385.png","contentUrl":"https:\/\/fhi.nl\/app\/uploads\/2024\/06\/3-e1722349014385.png","width":732,"height":136,"caption":"FHI, federatie van technologiebranches"},"image":{"@id":"https:\/\/fhi.nl\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/fhi-federation-of-technology-branches","https:\/\/www.instagram.com\/fhi_nl\/"]}]}},"_links":{"self":[{"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/news\/68708","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/types\/news"}],"version-history":[{"count":0,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/news\/68708\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/media\/68709"}],"wp:attachment":[{"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/media?parent=68708"}],"wp:term":[{"taxonomy":"branches","embeddable":true,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/branches?post=68708"},{"taxonomy":"events","embeddable":true,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/events?post=68708"},{"taxonomy":"secretariat","embeddable":true,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/secretariat?post=68708"},{"taxonomy":"categories","embeddable":true,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/categories?post=68708"},{"taxonomy":"themes","embeddable":true,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/themes_tax?post=68708"},{"taxonomy":"content_types","embeddable":true,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/content_types?post=68708"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}