{"id":73330,"date":"2025-09-22T13:26:00","date_gmt":"2025-09-22T11:26:00","guid":{"rendered":"https:\/\/fhi.nl\/nieuws\/hoe-selecteer-je-de-juiste-datakabel-voor-je-industriele-toepassing-2\/"},"modified":"2025-09-22T13:42:18","modified_gmt":"2025-09-22T11:42:18","slug":"hoe-selecteer-je-de-juiste-datakabel-voor-je-industriele-toepassing-2","status":"publish","type":"news","link":"https:\/\/fhi.nl\/en\/news\/hoe-selecteer-je-de-juiste-datakabel-voor-je-industriele-toepassing-2\/","title":{"rendered":"How do you select the right data cable for your industrial application?"},"content":{"rendered":"<header id=\"header\" class=\"header header--high header--branch\">\n\n\t\t\t\t\t\t\t\t\t\t<div class=\"header__background header__background--high\">\n\t\t\t\t\t<img decoding=\"async\" class=\"header__background-image\" src=\"https:\/\/fhi.nl\/app\/uploads\/2025\/09\/Techniker-Industrie_newsroom_big.jpeg\" alt=\"\">\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\n\t\n\t<div class=\"container\">\n\t\t<div class=\"header__content\">\n\t\t\t<div class=\"header__first header__first--alone\">\n\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<h1 class=\"header__title\" >\n\t\t\t\t\tHow do you select the right data cable for your industrial application?\t\t\t\t<\/h1>\n\n\t\t\t\t<div class=\"header__dots-line\">\n\t\t\t\t\t<svg width=\"431\" height=\"9\" viewbox=\"0 0 431 9\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M430.799 4.192a1.136 1.136 0 1 1-2.272-.001 1.136 1.136 0 0 1 2.272 0Zm-27.272 0a1.135 1.135 0 1 1-2.27 0 1.135 1.135 0 0 1 2.27 0Zm-27.27 0a1.136 1.136 0 1 1-2.272-.001 1.136 1.136 0 0 1 2.272 0Zm-27.272 0a1.39 1.39 0 1 1-2.78 0 1.39 1.39 0 0 1 2.78 0Zm-27.78 0a1.645 1.645 0 1 1-3.29 0 1.645 1.645 0 0 1 3.29 0Zm-28.29 0a1.9 1.9 0 1 1-3.799 0 1.9 1.9 0 0 1 3.799 0Zm-28.799 0a2.154 2.154 0 1 1-4.308 0 2.154 2.154 0 0 1 4.308 0Zm-29.308 0a2.41 2.41 0 1 1-4.819 0 2.41 2.41 0 0 1 4.819 0Zm-29.819 0a2.663 2.663 0 1 1-5.326.001 2.663 2.663 0 0 1 5.326-.001Zm-30.327 0a2.919 2.919 0 1 1-5.837 0 2.919 2.919 0 0 1 5.837 0Zm-30.837 0a3.173 3.173 0 1 1-6.345.001 3.173 3.173 0 0 1 6.345 0Zm-31.346 0a3.428 3.428 0 1 1-6.856 0 3.428 3.428 0 0 1 6.856 0Zm-31.856 0a3.683 3.683 0 1 1-7.365 0 3.683 3.683 0 0 1 7.365 0Zm-32.365 0a3.937 3.937 0 1 1-7.875 0 3.937 3.937 0 0 1 7.875 0Zm-32.874 0a4.192 4.192 0 1 1-8.384 0 4.192 4.192 0 0 1 8.384 0Z\" fill=\"#FFF960\"\/><\/svg>\t\t\t\t<\/div>\n\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div>\n\n\t\t\t\n\t\t<\/div>\n\t<\/div>\n<\/header>\n\n\t<div class=\"header__meta\">\n\t<div class=\"container\">\n\t\t<div class=\"header__meta__category\">\n\n\t\t\t\t\t\t\t<div class=\"header__meta__detail\">\n\t\t\t\t\t<div>Branch<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/fhi.nl\/en\/kennishub\/?_branches_kennishub=industriele-automatisering\" class=\"header__meta__detail--branch\">\n\t\t\t\t\t\t\t\tIndustrial automation\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t<div class=\"header__meta__detail\">\n\t\t\t\t\t<div>Subject<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/fhi.nl\/en\/kennishub\/?_onderwerp_kennishub=industriele-automatisering\" class=\"header__meta__detail--categorie\">\n\t\t\t\t\t\t\t\tIndustrial automation\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\n\t\t<\/div>\n\t<\/div>\n<\/div>\n\n<div class=\"text bg--white\">\n\t<div class=\"container\">\n\t\t\t\t\t\t\t\t\t\t\t<div class=\"text__content text__content--1-col\">\n\t\t\t<p>Not all data cables are the same. Many users only realize this when they experience data transfer disruptions and errors in their industrial applications. In this article you will learn what the most common mistakes are when selecting an industrial Ethernet or bus cable and how to avoid them.<\/p><div class=\"newsroom-small-padding section-full section-padding\" data-test-id=\"394162\"><div class=\"container\"><div class=\"section-content\"><div class=\"row p-lr15 text-image-flex\"><div class=\"col-12 p-lr15\"><div class=\"text-black p-t15 table table-hover\"><p>All cables and wires that contribute in any way to communications are commonly referred to as data cables. However, there are significant differences, such as the completely different structures of copper and fiber optic cables. Copper data cables come in many different types, such as low-frequency cables, coaxial cables, telephone cables, bus cables, various Ethernet systems, or microwave cables for special applications that require transmission in the gigahertz range. Selecting the wrong cable can quickly lead to costly disruptions and errors.<\/p><p>In general, data cables are low capacity cables. This means that as little electrical energy as possible is stored in the cable during data transmission. This electrical energy has a negative effect on signal quality. The capacity partly depends on the insulation material of the cable. Modern bus and Ethernet cables mainly use materials such as PE (polyethylene) or PP (polypropylene), which provide particularly good insulation, which is determined by measuring the dielectric constant (\u03b5r). The lower this value, the better the material insulates and the lower the capacity of the cable. This allows thinner insulation to be used with the same dielectric strength.<\/p><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"newsroom-small-padding section-full section-padding\" data-test-id=\"394162\"><div class=\"container\"><div class=\"section-content\"><div class=\"row p-lr15 text-image-flex\"><h2 class=\"col-sm-12 headline_small\">A comparison of cable insulation materials<\/h2><div class=\"col-12 p-lr15\"><div class=\"text-black p-t15 table table-hover\"><table class=\"mce-item-table\"><tbody><tr class=\"vertical-align-top\"><td><strong>Material<\/strong><\/td><td><strong>VDE label<\/strong><\/td><td><strong>Dielectric Constant<\/strong><\/td><td><strong>Halogen free<\/strong><\/td><\/tr><tr class=\"vertical-align-top\"><td>PVC<\/td><td>Y<\/td><td>3.6-6<\/td><td>no<\/td><\/tr><tr class=\"vertical-align-top\"><td>PVC +90\u00b0C<\/td><td>Yw<\/td><td>4-6.5<\/td><td>no<\/td><\/tr><tr class=\"vertical-align-top\"><td>P.E<\/td><td>2Y<\/td><td>2.3<\/td><td>yes<\/td><\/tr><tr class=\"vertical-align-top\"><td>PE foamed<\/td><td>02Y<\/td><td>1.6-1.8<\/td><td>yes<\/td><\/tr><tr class=\"vertical-align-top\"><td>PP<\/td><td>9Y<\/td><td>2.3-2.4<\/td><td>yes<\/td><\/tr><tr class=\"vertical-align-top\"><td>PP foamed<\/td><td><br><\/td><td>1.6-1.8<\/td><td>yes<\/td><\/tr><tr class=\"vertical-align-top\"><td>PUR<\/td><td>11Y<\/td><td>4-7<\/td><td>yes*<\/td><\/tr><tr class=\"vertical-align-top\"><td>FEP<\/td><td>6Y<\/td><td>2.1<\/td><td>no<\/td><\/tr><tr class=\"vertical-align-top\"><td colspan=\"4\"><sup>*Dependent on flame retardants used<\/sup><\/td><\/tr><\/tbody><\/table><p>Clean data transmission is achieved through proper cable construction. A solid wire, which is perfectly round and has a uniform diameter, provides the best electrical performance. For industrial Ethernet and bus cables, the AWG construction is preferred, because this flexible construction results in a round conductor. Metric cables are not suitable for this application because they have a bonded construction and are not round. This leads to variable capacities that strongly influence data transmission at high frequencies.<\/p><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"newsroom-small-padding section-full section-padding\" data-test-id=\"394162\"><div class=\"container\"><div class=\"section-content\"><div class=\"row p-lr15 text-image-flex\"><h2 class=\"col-sm-12 headline_small\">Common Mistakes When Selecting Industrial Ethernet and Bus Cables<\/h2><div class=\"col-12 p-lr15\"><div class=\"text-black p-t15 table table-hover\"><h3>1. <strong>Low-frequency cables for high-frequency applications<\/strong><\/h3><p>Selecting low-frequency cables for high-frequency Ethernet connections is a common cause of data transmission failure. These cables also have low capacitance, but exhibit a different characteristic impedance than what is required by the Ethernet standard. This leads to a mismatch or discontinuity. In low-frequency data cables, all pairs are laid in parallel. This means that all four laying lengths are the same. Ethernet cables used in high-frequency applications must also be optimally decoupled. This is achieved by using four different laying lengths, which are measured individually. The positions of the twisted pairs within the overall construction must also be taken into account.<\/p><p><br><\/p><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"newsroom-small-padding section-full section-padding\" data-test-id=\"394162\"><div class=\"container\"><div class=\"section-content\"><div class=\"row p-lr15 text-image-flex\"><div class=\"col-12 p-lr15\"><div class=\"p-t15 p-b20\"><div class=\"item\"><div class=\"ow-img\"><img decoding=\"async\" title=\"\" src=\"https:\/\/www.helukabel.de\/HELUKABEL\/Bilder\/Imagebilder\/Schlechte-und-Gute-Entkopplung_any_large.webp\" alt=\"Poor and Good Decoupling\" data-mce-src=\"https:\/\/www.helukabel.de\/HELUKABEL\/Bilder\/Imagebilder\/Schlechte-und-Gute-Entkopplung_any_large.webp\"><\/div><\/div><div class=\"image-subline\">Bad disconnection (left) and good disconnection (right)<\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"newsroom-small-padding section-full section-padding\" data-test-id=\"394162\"><div class=\"container\"><div class=\"section-content\"><div class=\"row p-lr15 text-image-flex\"><div class=\"col-12 p-lr15\"><div class=\"text-black p-t15 table table-hover\"><h3><strong>2. Classic twisted pairs instead of a star quad<\/strong><\/h3><p>Many industrial communications standards, such as PROFInet, EtherCAT or SERCOS III, use cables with two twisted pairs twisted into a star-quad for data transmission. All four cores are turned into a perfectly round shape. The advantage of this is that there are no differences in transit time. This is in contrast to classic twisted pairs, where the individual twisted pairs must have two different twisted lengths due to the required decoupling. If the wrong twisted pair cable is used, it can cause problems with transmission and throughput times.<\/p><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"newsroom-small-padding section-full section-padding\" data-test-id=\"394162\"><div class=\"container\"><div class=\"section-content\"><div class=\"row p-lr15 text-image-flex\"><div class=\"col-12 col-md-6\"><div class=\"p-t15 p-b20\"><div class=\"item\"><div class=\"ow-img\"><img decoding=\"async\" title=\"\" src=\"https:\/\/www.helukabel.de\/HELUKABEL\/Bilder\/Imagebilder\/2-Paar_any_small.webp\" alt=\"2 Pairs\" data-mce-src=\"https:\/\/www.helukabel.de\/HELUKABEL\/Bilder\/Imagebilder\/2-Paar_any_small.webp\"><\/div><\/div><\/div><\/div><div class=\"col-12 col-md-6 text-image-flex\"><div class=\"text-black p-t15 table table-hover\"><h3><strong>2 Couples<\/strong><\/h3><ul class=\"list-simple p-l15\"><li>4 x Core diameter<\/li><li>3 x Stranding<\/li><li>Pairs according to illustration<\/li><li>Simple<\/li><li>Different signal transit times<\/li><\/ul><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"newsroom-small-padding section-full section-padding\" data-test-id=\"394162\"><div class=\"container\"><div class=\"section-content\"><div class=\"row p-lr15 text-image-flex\"><div class=\"col-12 col-md-6\"><div class=\"p-t15 p-b20\"><div class=\"item\"><div class=\"ow-img\"><img decoding=\"async\" title=\"\" src=\"https:\/\/www.helukabel.de\/HELUKABEL\/Bilder\/Produktbilder\/Sternvierer_any_small.webp\" alt=\"Star Quad\" data-mce-src=\"https:\/\/www.helukabel.de\/HELUKABEL\/Bilder\/Produktbilder\/Sternvierer_any_small.webp\"><\/div><\/div><\/div><\/div><div class=\"col-12 col-md-6 text-image-flex\"><div class=\"text-black p-t15 table table-hover\"><h3><strong>Star quad<\/strong><\/h3><ul class=\"list-simple p-l15\"><li>2.4 Core diameter<\/li><li>1 x Stranding<\/li><li>Diagonal cores create the electrical pair: white\/blue and orange\/yellow<\/li><li>Identical signal transit times<\/li><\/ul><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"newsroom-small-padding section-full section-padding\" data-test-id=\"394162\"><div class=\"container\"><div class=\"section-content\"><div class=\"row p-lr15 text-image-flex\"><div class=\"col-12 p-lr15\"><div class=\"text-black p-t15 table table-hover\"><p>In star quads, the nuclei that are diagonally opposite each other form the electrical pair. If this rule is ignored when connecting the cable, the characteristic impedance and near-end crosstalk (NEXT) of the cable will be changed, which may reduce transmission quality. Even shielded four-core sensor cables are not suitable for use as high-frequency industrial Ethernet or bus cables, despite their construction appearing similar at first glance. The difference is that the core insulation strength is not intended for Ethernet, and the stranding is not perfectly circular in construction. This results in an inadequately functioning cable due to unsuitable characteristic impedance, NEXT and cable attenuation.<\/p><h3><strong>3. Too Long Cable or Too Small Diameter<\/strong><\/h3><p>Another classic example is segments that are too long. According to the Ethernet standard, a repeater must be used after a maximum length of 100 meters. This receives the weak signal and retransmits it at full strength. In practice, segments with lengths longer than 100 meters may occur, but these do not meet the applicable standards. In these cases, rising temperatures, aging and other factors can quickly lead to defects or malfunctions. Thinner cables with AWG 26 diameters are limited to 60 \u2013 70 meters. It is important to remember that every plug connection is a lossy connection due to attenuation and reflection, which reduces range.<\/p><h3><strong>4. Wrong Plug<\/strong><\/h3><p>It is common for non-standard and untested connectors to be used in Ethernet applications, such as D-Sub or M12 connectors, which are A-coded with an 8-pin design. Although these plugs can transfer data, the quality is significantly reduced due to lower near-end crosstalk (NEXT). The reason for this is the position of the middle pin, which is not in accordance with standards and hinders data transmission.<\/p><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"newsroom-small-padding section-full section-padding\" data-test-id=\"394162\"><div class=\"container\"><div class=\"section-content\"><div class=\"row p-lr15 text-image-flex\"><div class=\"col-12 p-lr15\"><div class=\"p-t15 p-b20\"><div class=\"item\"><div class=\"ow-img\"><img decoding=\"async\" title=\"\" src=\"https:\/\/www.helukabel.de\/HELUKABEL\/Bilder\/Imagebilder\/Overview_connector_face_EN_any_large.webp\" alt=\"Overview different connector faces\" data-mce-src=\"https:\/\/www.helukabel.de\/HELUKABEL\/Bilder\/Imagebilder\/Overview_connector_face_EN_any_large.webp\"><\/div><\/div><\/div><\/div><\/div><\/div><\/div><\/div><div class=\"newsroom-small-padding section-full section-padding\" data-test-id=\"394162\"><div class=\"container\"><div class=\"section-content\"><div class=\"row p-lr15 text-image-flex\"><div class=\"col-12 p-lr15\"><div class=\"text-black p-t15 table table-hover\"><p>According to Ethernet standards, permitted connector connections for the best data cables are shielded plugs\/sockets:<\/p><ul class=\"list-simple p-l15\"><li>RJ45 4-pin (100 Mbit 4-pin)<\/li><li>RJ45 8-pin (Gbit 8-pin)<\/li><li>D-coded M8 &amp; M12 (100 Mbit)<\/li><li>A-coded M8 4-pin (100 Mbit)<\/li><li>P-coded M12 (100 Mbit)<\/li><li>X-coded M12 (Gbit)<\/li><li>Ix Industrial (Gbit)<\/li><li>Mini IO<\/li><li>SPE (Single Pair Ethernet)<\/li><\/ul><p>In addition, there are various standards such as PROFInet, EtherCAT, or SPE (Single Pair Ethernet) that can transfer data and power via one hybrid plug. These comply with IEC standards, have been evaluated by the appropriate organizations, or are in the standardization phase.<\/p><p>Standardized Hybrid Ethernet Plugs:<\/p><ul class=\"list-simple p-l15\"><li>M8 SPE according to IEC 63171-6<\/li><li>M12 SPE according to IEC 63171-7<\/li><li>Y-coded M12 according to IEC 61076-2-113<\/li><li>M23 according to IEC 61076-2-117<\/li><li>RJ45 Hybrid according to IEC 61076-3-106<\/li><li>Ix Industrial according to IEC 61076-3-124<\/li><\/ul><p>Some plug manufacturers have their own hybrid solutions in their portfolio that are not standardized but have been tested and evaluated for Ethernet compliance. As a basic principle, it is always recommended to stick to standardized and evaluated Ethernet plug connections.<\/p><p><strong>Important points to remember: <\/strong><\/p><p>When selecting data cables for industrial applications, users must adhere to appropriate standards to avoid interference and defects. Users should also pay attention to the lengths of the individual segments, the number of plugs, and the different diameters of installation and patch cables. In addition, aging of individual components can lead to a decrease in transmission quality and interruptions in the long term. With 45 years of experience, HELUKABEL is an expert in connection technology and is ready to support users in finding the perfect industrial Ethernet or bus cables for their application.<\/p><\/div><\/div><\/div><\/div><\/div><\/div>\t\t<\/div>\n\t<\/div>\n<\/div>\r\n\t<div class=\"articles bg--offwhite automatic\">\r\n\t\t<div class=\"container\">\r\n\t\t\t<div class=\"articles__header\">\r\n\t\t\t\t\t\t\t\t\t<div class='heading-wrapper'><svg width=\"13\" height=\"13\" viewbox=\"0 0 13 13\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><circle cx=\"6.394\" cy=\"6.5\" r=\"6.394\" fill=\"#000\"\/><\/svg><h2>Related articles<\/h2><\/div>\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"\/en\/profiel\/helukabel-b-v\/\" class=\"button button--outline\">view profile<\/a>\r\n\t\t\t\t\t\t\t<\/div>\r\n\t\t\t\t\t\t<div class=\"post-grid post-grid--no-padding\">\r\n\t\t\t\t\n<a class=\"single-item single-item__articles\" href=\"https:\/\/fhi.nl\/en\/news\/update-electronics-applications-2021-geef-uw-voorkeur-op-de-beursvloer-door\/\" data-id=\"39498\">\n\t<div class=\"single-item__articles-icon\">\n\t\t<svg width=\"103\" height=\"103\" viewbox=\"0 0 103 103\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\">\n<path fill-rule=\"evenodd\" clip-rule=\"evenodd\" d=\"M49.5 98.9587V82.3076C33.3844 81.2758 20.6328 67.878 20.6328 51.5019C20.6328 35.1258 33.3844 21.728 49.5 20.6962V4.04134C24.1941 5.08952 4 25.9365 4 51.5C4 77.0635 24.1941 97.9105 49.5 98.9587ZM53.5 78.2983V61.8096H76.3238C72.5238 70.9498 63.8222 77.5397 53.5 78.2983ZM49.5 78.298V61.8096H26.681C30.4804 70.9484 39.1799 77.5377 49.5 78.298ZM47.0728 57.8096H25.3773C24.8906 55.7865 24.6328 53.6743 24.6328 51.5019C24.6328 37.3358 35.5955 25.7301 49.5 24.7058V37.013H34.0466C33.2709 37.013 32.5653 37.4615 32.2359 38.1637C31.9065 38.8659 32.0128 39.6952 32.5086 40.2916L47.0728 57.8096ZM55.9249 57.8096H77.6274C78.1141 55.7865 78.3719 53.6743 78.3719 51.5019C78.3719 37.3342 67.4068 25.7275 53.5 24.7055V37.013H68.9511C69.7268 37.013 70.4324 37.4615 70.7618 38.1637C71.0912 38.8659 70.9849 39.6952 70.4891 40.2916L55.9249 57.8096ZM53.5 82.3079V98.9587C78.8059 97.9105 99 77.0635 99 51.5C99 25.9365 78.8059 5.08952 53.5 4.04134V20.6959C69.6178 21.7254 82.3719 35.1242 82.3719 51.5019C82.3719 67.8796 69.6178 81.2784 53.5 82.3079ZM0 51.5C0 23.7271 21.9843 1.08883 49.5 0.0381213V0H51.5H53.5V0.0381213C81.0157 1.08883 103 23.7271 103 51.5C103 79.9427 79.9427 103 51.5 103C23.0573 103 0 79.9427 0 51.5ZM38.3102 41.013H64.6875L51.4989 56.8765L38.3102 41.013Z\" fill=\"#2DD881\"\/>\n<\/svg>\n\t<\/div>\n\t<div class=\"single-item__articles-title\"><div class='heading-wrapper'><h3>Electronics &amp; Applications Update 2021: indicate your preference on the exhibition floor<\/h3><\/div><\/div>\n\t<div class=\"single-item__articles-terms\">\n\t\t\n\t\t\n\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">Industrial Electronics<\/span>\n\t\t\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">Electronics &amp; Applications<\/span>\n\t\t\t\t\t<\/div>\n\t<div class=\"single-item__articles-author-date-wrapper\">\n\t\t\t\t\t<div class=\"single-item__articles-author\">\n\t\t\t\tFHI, Federation of Technology Industries\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"single-item__articles-date\">\n\t\t\t\tMarch 23, 2021\t\t\t<\/div>\n\t\t\t<\/div>\n<\/a>\n\n<a class=\"single-item single-item__articles\" href=\"https:\/\/fhi.nl\/en\/news\/university-racing-eindhoven-revolutionizes-electric-racing\/\" data-id=\"62541\">\n\t<div class=\"single-item__articles-icon\">\n\t\t<svg width=\"103\" height=\"103\" viewbox=\"0 0 103 103\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\">\n<path fill-rule=\"evenodd\" clip-rule=\"evenodd\" d=\"M49.5 98.9587V82.3076C33.3844 81.2758 20.6328 67.878 20.6328 51.5019C20.6328 35.1258 33.3844 21.728 49.5 20.6962V4.04134C24.1941 5.08952 4 25.9365 4 51.5C4 77.0635 24.1941 97.9105 49.5 98.9587ZM53.5 78.2983V61.8096H76.3238C72.5238 70.9498 63.8222 77.5397 53.5 78.2983ZM49.5 78.298V61.8096H26.681C30.4804 70.9484 39.1799 77.5377 49.5 78.298ZM47.0728 57.8096H25.3773C24.8906 55.7865 24.6328 53.6743 24.6328 51.5019C24.6328 37.3358 35.5955 25.7301 49.5 24.7058V37.013H34.0466C33.2709 37.013 32.5653 37.4615 32.2359 38.1637C31.9065 38.8659 32.0128 39.6952 32.5086 40.2916L47.0728 57.8096ZM55.9249 57.8096H77.6274C78.1141 55.7865 78.3719 53.6743 78.3719 51.5019C78.3719 37.3342 67.4068 25.7275 53.5 24.7055V37.013H68.9511C69.7268 37.013 70.4324 37.4615 70.7618 38.1637C71.0912 38.8659 70.9849 39.6952 70.4891 40.2916L55.9249 57.8096ZM53.5 82.3079V98.9587C78.8059 97.9105 99 77.0635 99 51.5C99 25.9365 78.8059 5.08952 53.5 4.04134V20.6959C69.6178 21.7254 82.3719 35.1242 82.3719 51.5019C82.3719 67.8796 69.6178 81.2784 53.5 82.3079ZM0 51.5C0 23.7271 21.9843 1.08883 49.5 0.0381213V0H51.5H53.5V0.0381213C81.0157 1.08883 103 23.7271 103 51.5C103 79.9427 79.9427 103 51.5 103C23.0573 103 0 79.9427 0 51.5ZM38.3102 41.013H64.6875L51.4989 56.8765L38.3102 41.013Z\" fill=\"#2DD881\"\/>\n<\/svg>\n\t<\/div>\n\t<div class=\"single-item__articles-title\"><div class='heading-wrapper'><h3>University Racing Eindhoven Revolutionizes Electric Racing<\/h3><\/div><\/div>\n\t<div class=\"single-item__articles-terms\">\n\t\t\n\t\t\n\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">Industrial Electronics<\/span>\n\t\t\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">Design Automation &amp; Embedded Systems Event<\/span>\n\t\t\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">Members content<\/span>\n\t\t\t\t\t<\/div>\n\t<div class=\"single-item__articles-author-date-wrapper\">\n\t\t\t\t\t<div class=\"single-item__articles-author\">\n\t\t\t\tEurocircuits NV\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"single-item__articles-date\">\n\t\t\t\t31 January 2025\t\t\t<\/div>\n\t\t\t<\/div>\n<\/a>\n\n<a class=\"single-item single-item__articles\" href=\"https:\/\/fhi.nl\/en\/news\/betronic-en-innotractor-ontwikkelen-modulair-iot-concept\/\" data-id=\"39454\">\n\t<div class=\"single-item__articles-icon\">\n\t\t<svg width=\"103\" height=\"103\" viewbox=\"0 0 103 103\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\">\n<path fill-rule=\"evenodd\" clip-rule=\"evenodd\" d=\"M49.5 98.9587V82.3076C33.3844 81.2758 20.6328 67.878 20.6328 51.5019C20.6328 35.1258 33.3844 21.728 49.5 20.6962V4.04134C24.1941 5.08952 4 25.9365 4 51.5C4 77.0635 24.1941 97.9105 49.5 98.9587ZM53.5 78.2983V61.8096H76.3238C72.5238 70.9498 63.8222 77.5397 53.5 78.2983ZM49.5 78.298V61.8096H26.681C30.4804 70.9484 39.1799 77.5377 49.5 78.298ZM47.0728 57.8096H25.3773C24.8906 55.7865 24.6328 53.6743 24.6328 51.5019C24.6328 37.3358 35.5955 25.7301 49.5 24.7058V37.013H34.0466C33.2709 37.013 32.5653 37.4615 32.2359 38.1637C31.9065 38.8659 32.0128 39.6952 32.5086 40.2916L47.0728 57.8096ZM55.9249 57.8096H77.6274C78.1141 55.7865 78.3719 53.6743 78.3719 51.5019C78.3719 37.3342 67.4068 25.7275 53.5 24.7055V37.013H68.9511C69.7268 37.013 70.4324 37.4615 70.7618 38.1637C71.0912 38.8659 70.9849 39.6952 70.4891 40.2916L55.9249 57.8096ZM53.5 82.3079V98.9587C78.8059 97.9105 99 77.0635 99 51.5C99 25.9365 78.8059 5.08952 53.5 4.04134V20.6959C69.6178 21.7254 82.3719 35.1242 82.3719 51.5019C82.3719 67.8796 69.6178 81.2784 53.5 82.3079ZM0 51.5C0 23.7271 21.9843 1.08883 49.5 0.0381213V0H51.5H53.5V0.0381213C81.0157 1.08883 103 23.7271 103 51.5C103 79.9427 79.9427 103 51.5 103C23.0573 103 0 79.9427 0 51.5ZM38.3102 41.013H64.6875L51.4989 56.8765L38.3102 41.013Z\" fill=\"#2DD881\"\/>\n<\/svg>\n\t<\/div>\n\t<div class=\"single-item__articles-title\"><div class='heading-wrapper'><h3>Betronic and InnoTractor develop modular IoT concept<\/h3><\/div><\/div>\n\t<div class=\"single-item__articles-terms\">\n\t\t\n\t\t\n\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">Industrial Electronics<\/span>\n\t\t\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">Development club<\/span>\n\t\t\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">Antennas<\/span>\n\t\t\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">Assemblies, modules<\/span>\n\t\t\t\t\t<\/div>\n\t<div class=\"single-item__articles-author-date-wrapper\">\n\t\t\t\t\t<div class=\"single-item__articles-author\">\n\t\t\t\tBetronic\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"single-item__articles-date\">\n\t\t\t\tMarch 25, 2021\t\t\t<\/div>\n\t\t\t<\/div>\n<\/a>\n\t\t\t<\/div>\r\n\t\t<\/div>\r\n\t<\/div>","protected":false},"excerpt":{"rendered":"<p>In this article, you&#039;ll learn what the most common mistakes are when selecting an industrial Ethernet or bus cable and how to avoid them.<\/p>","protected":false},"featured_media":73331,"template":"","branches":[12],"events":[497],"secretariat":[],"categories":[58],"themes_tax":[509,510,523],"content_types":[514],"class_list":["post-73330","news","type-news","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Hoe selecteer je de juiste datakabel voor je industri\u00eble toepassing?<\/title>\n<meta name=\"description\" content=\"In dit artikel leert u wat de meest voorkomende fouten zijn bij het selecteren van een industri\u00eble Ethernet- of buskabel en hoe u deze kunt vermijden.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.helukabel.nl\/nl-nl\/nieuws\/post\/selecteren-verkeerde-datakabel.html\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Hoe selecteer je de juiste datakabel voor je industri\u00eble toepassing?\" \/>\n<meta property=\"og:description\" content=\"In dit artikel leert u wat de meest voorkomende fouten zijn bij het selecteren van een industri\u00eble Ethernet- of buskabel en hoe u deze kunt vermijden.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.helukabel.nl\/nl-nl\/nieuws\/post\/selecteren-verkeerde-datakabel.html\" \/>\n<meta property=\"og:site_name\" content=\"FHI, Federatie van technologiebranches\" \/>\n<meta property=\"article:modified_time\" content=\"2025-09-22T11:42:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/fhi.nl\/app\/uploads\/2025\/09\/Techniker-Industrie_newsroom_big.jpeg\" \/>\n\t<meta property=\"og:image:width\" content=\"1132\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/fhi.nl\\\/nieuws\\\/hoe-selecteer-je-de-juiste-datakabel-voor-je-industriele-toepassing-2\\\/\",\"url\":\"https:\\\/\\\/www.helukabel.nl\\\/nl-nl\\\/nieuws\\\/post\\\/selecteren-verkeerde-datakabel.html\",\"name\":\"Hoe selecteer je de juiste datakabel voor je industri\u00eble toepassing?\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/fhi.nl\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.helukabel.nl\\\/nl-nl\\\/nieuws\\\/post\\\/selecteren-verkeerde-datakabel.html#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.helukabel.nl\\\/nl-nl\\\/nieuws\\\/post\\\/selecteren-verkeerde-datakabel.html#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/fhi.nl\\\/app\\\/uploads\\\/2025\\\/09\\\/Techniker-Industrie_newsroom_big.jpeg\",\"datePublished\":\"2025-09-22T11:26:00+00:00\",\"dateModified\":\"2025-09-22T11:42:18+00:00\",\"description\":\"In dit artikel leert u wat de meest voorkomende fouten zijn bij het selecteren van een industri\u00eble Ethernet- of buskabel en hoe u deze kunt vermijden.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.helukabel.nl\\\/nl-nl\\\/nieuws\\\/post\\\/selecteren-verkeerde-datakabel.html#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.helukabel.nl\\\/nl-nl\\\/nieuws\\\/post\\\/selecteren-verkeerde-datakabel.html\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.helukabel.nl\\\/nl-nl\\\/nieuws\\\/post\\\/selecteren-verkeerde-datakabel.html#primaryimage\",\"url\":\"https:\\\/\\\/fhi.nl\\\/app\\\/uploads\\\/2025\\\/09\\\/Techniker-Industrie_newsroom_big.jpeg\",\"contentUrl\":\"https:\\\/\\\/fhi.nl\\\/app\\\/uploads\\\/2025\\\/09\\\/Techniker-Industrie_newsroom_big.jpeg\",\"width\":1132,\"height\":400},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.helukabel.nl\\\/nl-nl\\\/nieuws\\\/post\\\/selecteren-verkeerde-datakabel.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/fhi.nl\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Nieuws\",\"item\":\"https:\\\/\\\/fhi.nl\\\/nieuws\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Hoe selecteer je de juiste datakabel voor je industri\u00eble toepassing?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/fhi.nl\\\/#website\",\"url\":\"https:\\\/\\\/fhi.nl\\\/\",\"name\":\"FHI, federatie van technologiebranches\",\"description\":\"Nederlandse branchevereniging voor technologiebranches\",\"publisher\":{\"@id\":\"https:\\\/\\\/fhi.nl\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/fhi.nl\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/fhi.nl\\\/#organization\",\"name\":\"FHI, federatie van technologiebranches\",\"url\":\"https:\\\/\\\/fhi.nl\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/fhi.nl\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/fhi.nl\\\/app\\\/uploads\\\/2024\\\/06\\\/3-e1722349014385.png\",\"contentUrl\":\"https:\\\/\\\/fhi.nl\\\/app\\\/uploads\\\/2024\\\/06\\\/3-e1722349014385.png\",\"width\":732,\"height\":136,\"caption\":\"FHI, federatie van technologiebranches\"},\"image\":{\"@id\":\"https:\\\/\\\/fhi.nl\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/fhi-federation-of-technology-branches\",\"https:\\\/\\\/www.instagram.com\\\/fhi_nl\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How do you select the right data cable for your industrial application?","description":"In this article, you&#039;ll learn what the most common mistakes are when selecting an industrial Ethernet or bus cable and how to avoid them.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.helukabel.nl\/nl-nl\/nieuws\/post\/selecteren-verkeerde-datakabel.html","og_locale":"en_GB","og_type":"article","og_title":"Hoe selecteer je de juiste datakabel voor je industri\u00eble toepassing?","og_description":"In dit artikel leert u wat de meest voorkomende fouten zijn bij het selecteren van een industri\u00eble Ethernet- of buskabel en hoe u deze kunt vermijden.","og_url":"https:\/\/www.helukabel.nl\/nl-nl\/nieuws\/post\/selecteren-verkeerde-datakabel.html","og_site_name":"FHI, Federatie van technologiebranches","article_modified_time":"2025-09-22T11:42:18+00:00","og_image":[{"width":1132,"height":400,"url":"https:\/\/fhi.nl\/app\/uploads\/2025\/09\/Techniker-Industrie_newsroom_big.jpeg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/fhi.nl\/nieuws\/hoe-selecteer-je-de-juiste-datakabel-voor-je-industriele-toepassing-2\/","url":"https:\/\/www.helukabel.nl\/nl-nl\/nieuws\/post\/selecteren-verkeerde-datakabel.html","name":"How do you select the right data cable for your industrial application?","isPartOf":{"@id":"https:\/\/fhi.nl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.helukabel.nl\/nl-nl\/nieuws\/post\/selecteren-verkeerde-datakabel.html#primaryimage"},"image":{"@id":"https:\/\/www.helukabel.nl\/nl-nl\/nieuws\/post\/selecteren-verkeerde-datakabel.html#primaryimage"},"thumbnailUrl":"https:\/\/fhi.nl\/app\/uploads\/2025\/09\/Techniker-Industrie_newsroom_big.jpeg","datePublished":"2025-09-22T11:26:00+00:00","dateModified":"2025-09-22T11:42:18+00:00","description":"In this article, you&#039;ll learn what the most common mistakes are when selecting an industrial Ethernet or bus cable and how to avoid them.","breadcrumb":{"@id":"https:\/\/www.helukabel.nl\/nl-nl\/nieuws\/post\/selecteren-verkeerde-datakabel.html#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.helukabel.nl\/nl-nl\/nieuws\/post\/selecteren-verkeerde-datakabel.html"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.helukabel.nl\/nl-nl\/nieuws\/post\/selecteren-verkeerde-datakabel.html#primaryimage","url":"https:\/\/fhi.nl\/app\/uploads\/2025\/09\/Techniker-Industrie_newsroom_big.jpeg","contentUrl":"https:\/\/fhi.nl\/app\/uploads\/2025\/09\/Techniker-Industrie_newsroom_big.jpeg","width":1132,"height":400},{"@type":"BreadcrumbList","@id":"https:\/\/www.helukabel.nl\/nl-nl\/nieuws\/post\/selecteren-verkeerde-datakabel.html#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/fhi.nl\/"},{"@type":"ListItem","position":2,"name":"Nieuws","item":"https:\/\/fhi.nl\/nieuws\/"},{"@type":"ListItem","position":3,"name":"Hoe selecteer je de juiste datakabel voor je industri\u00eble toepassing?"}]},{"@type":"WebSite","@id":"https:\/\/fhi.nl\/#website","url":"https:\/\/fhi.nl\/","name":"FHI, federation of technology industries","description":"Dutch trade association for technology industries","publisher":{"@id":"https:\/\/fhi.nl\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/fhi.nl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/fhi.nl\/#organization","name":"FHI, federation of technology industries","url":"https:\/\/fhi.nl\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/fhi.nl\/#\/schema\/logo\/image\/","url":"https:\/\/fhi.nl\/app\/uploads\/2024\/06\/3-e1722349014385.png","contentUrl":"https:\/\/fhi.nl\/app\/uploads\/2024\/06\/3-e1722349014385.png","width":732,"height":136,"caption":"FHI, federatie van technologiebranches"},"image":{"@id":"https:\/\/fhi.nl\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/fhi-federation-of-technology-branches","https:\/\/www.instagram.com\/fhi_nl\/"]}]}},"_links":{"self":[{"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/news\/73330","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/types\/news"}],"version-history":[{"count":0,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/news\/73330\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/media\/73331"}],"wp:attachment":[{"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/media?parent=73330"}],"wp:term":[{"taxonomy":"branches","embeddable":true,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/branches?post=73330"},{"taxonomy":"events","embeddable":true,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/events?post=73330"},{"taxonomy":"secretariat","embeddable":true,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/secretariat?post=73330"},{"taxonomy":"categories","embeddable":true,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/categories?post=73330"},{"taxonomy":"themes","embeddable":true,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/themes_tax?post=73330"},{"taxonomy":"content_types","embeddable":true,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/content_types?post=73330"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}