{"id":90689,"date":"2026-11-03T16:45:00","date_gmt":"2026-11-03T15:45:00","guid":{"rendered":"https:\/\/fhi.nl\/nieuws\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\/"},"modified":"2026-11-03T16:54:24","modified_gmt":"2026-11-03T15:54:24","slug":"tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power","status":"publish","type":"news","link":"https:\/\/fhi.nl\/en\/news\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\/","title":{"rendered":"Tektronix introduces fully regenerative dynamic test system for 800-volt AI data center power"},"content":{"rendered":"<header id=\"header\" class=\"header header--high header--branch\">\n\n\t\t\t\t\t\t\t\t\t\t<div class=\"header__background header__background--high\">\n\t\t\t\t\t<img decoding=\"async\" class=\"header__background-image\" src=\"https:\/\/fhi.nl\/app\/uploads\/2026\/11\/datacenter-ea.jpg\" alt=\"\">\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\n\t\n\t<div class=\"container\">\n\t\t<div class=\"header__content\">\n\t\t\t<div class=\"header__first\">\n\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t\n\t\t\t\t<h1 class=\"header__title\" >\n\t\t\t\t\tTektronix introduces fully regenerative dynamic test system for 800-volt AI data center power\t\t\t\t<\/h1>\n\n\t\t\t\t<div class=\"header__dots-line\">\n\t\t\t\t\t<svg width=\"431\" height=\"9\" viewbox=\"0 0 431 9\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M430.799 4.192a1.136 1.136 0 1 1-2.272-.001 1.136 1.136 0 0 1 2.272 0Zm-27.272 0a1.135 1.135 0 1 1-2.27 0 1.135 1.135 0 0 1 2.27 0Zm-27.27 0a1.136 1.136 0 1 1-2.272-.001 1.136 1.136 0 0 1 2.272 0Zm-27.272 0a1.39 1.39 0 1 1-2.78 0 1.39 1.39 0 0 1 2.78 0Zm-27.78 0a1.645 1.645 0 1 1-3.29 0 1.645 1.645 0 0 1 3.29 0Zm-28.29 0a1.9 1.9 0 1 1-3.799 0 1.9 1.9 0 0 1 3.799 0Zm-28.799 0a2.154 2.154 0 1 1-4.308 0 2.154 2.154 0 0 1 4.308 0Zm-29.308 0a2.41 2.41 0 1 1-4.819 0 2.41 2.41 0 0 1 4.819 0Zm-29.819 0a2.663 2.663 0 1 1-5.326.001 2.663 2.663 0 0 1 5.326-.001Zm-30.327 0a2.919 2.919 0 1 1-5.837 0 2.919 2.919 0 0 1 5.837 0Zm-30.837 0a3.173 3.173 0 1 1-6.345.001 3.173 3.173 0 0 1 6.345 0Zm-31.346 0a3.428 3.428 0 1 1-6.856 0 3.428 3.428 0 0 1 6.856 0Zm-31.856 0a3.683 3.683 0 1 1-7.365 0 3.683 3.683 0 0 1 7.365 0Zm-32.365 0a3.937 3.937 0 1 1-7.875 0 3.937 3.937 0 0 1 7.875 0Zm-32.874 0a4.192 4.192 0 1 1-8.384 0 4.192 4.192 0 0 1 8.384 0Z\" fill=\"#FFF960\"\/><\/svg>\t\t\t\t<\/div>\n\n\t\t\t\t\n\t\t\t\t\n\t\t\t<\/div>\n\n\t\t\t\t\t\t\t<div class=\"header__second\">\n\n\t\t\t\t\t\n\t\t\t\t\t\n\t\t\t\t\t\n\t\t\t\t\t\t\t\t\t\t\t<div class=\"header__branch-logos\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" src=\"https:\/\/fhi.nl\/app\/uploads\/2024\/02\/Industriele-elektronica.svg\" class=\"header__branch-logo\" alt=\"\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t\t\n\t\t\t\t\t\n\t\t\t\t\t\n\t\t\t\t<\/div>\n\t\t\t\n\t\t<\/div>\n\t<\/div>\n<\/header>\n\n\t<div class=\"header__meta\">\n\t<div class=\"container\">\n\t\t<div class=\"header__meta__category\">\n\n\t\t\t\t\t\t\t<div class=\"header__meta__detail\">\n\t\t\t\t\t<div>Branch<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/fhi.nl\/en\/kennishub\/?_branches_kennishub=industriele-elektronica\" class=\"header__meta__detail--branch\">\n\t\t\t\t\t\t\t\tIndustrial Electronics\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t\t<div class=\"header__meta__detail\">\n\t\t\t\t\t<div>Subject<\/div>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/fhi.nl\/en\/kennishub\/?_onderwerp_kennishub=datacenter-computerruimtes\" class=\"header__meta__detail--categorie\">\n\t\t\t\t\t\t\t\tData center\/computer rooms\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/fhi.nl\/en\/kennishub\/?_onderwerp_kennishub=industriele-elektronica\" class=\"header__meta__detail--categorie\">\n\t\t\t\t\t\t\t\tIndustrial Electronics\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/fhi.nl\/en\/kennishub\/?_onderwerp_kennishub=test-en-meetapparatuur\" class=\"header__meta__detail--categorie\">\n\t\t\t\t\t\t\t\tTest and measuring equipment\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\n\t\t<\/div>\n\t<\/div>\n<\/div>\n\n<div class=\"text bg--white\">\n\t<div class=\"container\">\n\t\t\t\t\t\t\t\t\t\t\t<div class=\"text__content text__content--1-col\">\n\t\t\t<div class=\"inner-block text option-text\" style=\"font-family: Manrope, sans-serif;color: #404040;font-size: 16px;font-style: normal;font-weight: 400;letter-spacing: normal;text-align: start;text-indent: 0px;text-transform: none;word-spacing: 0px;white-space: normal;background-color: #ffffff\">\r\n<div class=\"shading-container parbase aem-GridColumn aem-GridColumn--default--12\" style=\"font-family: Manrope, sans-serif;padding-bottom: 0px;margin-bottom: 0px;color: #000000\">\r\n<div class=\"row clearfix\" style=\"font-family: Manrope, sans-serif;padding-bottom: 0px;margin-bottom: 0px;color: #000000\">\r\n<div class=\"container\" style=\"font-family: Manrope, sans-serif;padding-bottom: 0px;margin-bottom: 0px;color: #000000\">\r\n<div class=\"row\" style=\"font-family: Manrope, sans-serif;padding-bottom: 0px;margin-bottom: 0px;color: #000000\">\r\n<div class=\"shading-container ni-padding-bottom-1x col-xs-12\" style=\"font-family: Manrope, sans-serif;padding-bottom: 0px;margin-bottom: 0px;color: #000000\">\r\n<div class=\"aem-Grid aem-Grid--12 aem-Grid--default--12\" style=\"font-family: Manrope, sans-serif;padding-bottom: 0px;margin-bottom: 0px;color: #000000\">\r\n<div class=\"title aem-GridColumn aem-GridColumn--default--12\" style=\"font-family: Manrope, sans-serif;padding-bottom: 0px;margin-bottom: 0px;color: #000000\">\r\n<div class=\"ni-notransform\" style=\"font-family: Manrope, sans-serif;padding-bottom: 0px;margin-bottom: 0px;color: #000000\">\r\n<h4 style=\"clear: both;font-size: clamp(20px, 5vw, 26px);line-height: 1.2;font-family: Manrope, sans-serif;font-weight: 300;color: #002145;margin: 0px;padding-bottom: 30px\">EA-ELR 21000 system pairs a new 1,000-volt electronic load with modular capacity from 30 kilowatts to 1.92 megawatts<\/h4>\r\n<p style=\"margin-bottom: 0.5em;font-size: 18px;line-height: 32px;font-weight: 400;font-family: Manrope, sans-serif;color: #000000;margin-top: 0px\">Tektronix has announced the EA-ELR 21000 Dynamic Test System, an auto-ranging, high-dynamic electronic load test system built on a fully regenerative architecture for validating the \u00b1400-volt and 800-volt DC power architectures emerging in AI data centers. Rather than dissipating absorbed test energy as heat, the system returns it to the grid with up to 95% regenerative efficiency, helping manufacturers conduct sustained high-power validation with less demand on lab power and cooling infrastructure. The system is built around the new EA-ELR 21000-80 4U HS, a 30-kilowatt regenerative electronic load module rated for up to 1,000 volts and up to 80 amps.<\/p>\r\n<p style=\"margin-bottom: 0.5em;font-size: 18px;line-height: 32px;font-weight: 400;font-family: Manrope, sans-serif;color: #000000;margin-top: 0px\">AI compute demand is reshaping data center power from the grid connection to the rack. As computing density rises, manufacturers are moving toward \u00b1400-volt sidecar designs and 800-volt DC distribution to reduce current conversion losses and the amount of copper needed to move power through the facility. At the same time, AI workloads create rapid, substantial changes in power demand that propagate through power shelves, power racks and infrastructure.<\/p>\r\n<p style=\"margin-bottom: 0px;font-size: 18px;line-height: 32px;font-weight: 400;font-family: Manrope, sans-serif;color: #000000;margin-top: 0px;padding-bottom: 0px\">For engineers developing this infrastructure, testing at higher power is only part of the challenge. They must reproduce fast-changing load conditions, evaluate stability and conversion performance at system voltage, and sustain demanding test programs without requiring proportionate increases in facility power, cooling and floor space.<\/p>\r\n<p style=\"margin-bottom: 0px;font-size: 18px;line-height: 32px;font-weight: 400;font-family: Manrope, sans-serif;color: #000000;margin-top: 0px;padding-bottom: 0px\">\u00a0<\/p>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>\r\n<div class=\"inner-block text option-text\" style=\"font-family: Manrope, sans-serif;color: #404040;font-size: 16px;font-style: normal;font-weight: 400;letter-spacing: normal;text-align: start;text-indent: 0px;text-transform: none;word-spacing: 0px;white-space: normal;background-color: #ffffff\">\r\n<p style=\"margin-bottom: 0.5em;font-size: 18px;line-height: 32px;font-weight: 400;font-family: Manrope, sans-serif;color: #000000;margin-top: 0px\">\u201cAI is making power architecture a strategic design decision,\u201d said James Hitchcock, Vice President and General Manager of the EA Portfolio at Tektronix. \u201cThe systems built for earlier generations of compute were not designed for the scale or pace of today&#039;s AI workloads, and power systems can no longer be treated as one-size-fits-all. The opportunity is to design and validate more efficient, resilient power architectures for the AI infrastructure being built today, with test systems that can keep pace with the speed and scale of the change.\u201d<\/p>\r\n<h3 style=\"clear: both;font-size: clamp(21px, 5vw, 32px);line-height: 1.2;font-family: Manrope, sans-serif;font-weight: 300;color: #002145;margin: 0px;padding-bottom: 30px\"><strong style=\"font-weight: bold;font-family: Manrope, sans-serif;padding-bottom: 0px;margin-bottom: 0px\">Dynamic validation without the traditional trade-off<\/strong><\/h3>\r\n<p style=\"margin-bottom: 0.5em;font-size: 18px;line-height: 32px;font-weight: 400;font-family: Manrope, sans-serif;color: #000000;margin-top: 0px\">Traditional high-power test approaches can force teams to choose between recreating fast-changing load behavior and managing the heat, cooling and grid demands of dissipative testing. Drawing on EA&#039;s longstanding expertise in ultra-high-power programmable DC test systems, the EA-ELR 21000 system combines high-dynamic load emulation with a fully regenerative architecture in one coordinated system.<\/p>\r\n<p style=\"margin-bottom: 0.5em;font-size: 18px;line-height: 32px;font-weight: 400;font-family: Manrope, sans-serif;color: #000000;margin-top: 0px\">That combination changes what is practical in the lab. High-dynamic load emulation helps engineers expose voltage droop, recovery and stability issues before power infrastructure reaches the data center. Its fully regenerative architecture helps them sustain those tests at high power, with the AC input primarily supporting system losses rather than full peak test power.<\/p>\r\n<p style=\"margin-bottom: 0.5em;font-size: 18px;line-height: 32px;font-weight: 400;font-family: Manrope, sans-serif;color: #000000;margin-top: 0px\">The EA-ELR 21000 Dynamic Test System delivers:<\/p>\r\n<ul>\r\n<li><strong style=\"font-weight: 500;color: #000000;font-family: Manrope, sans-serif;padding-bottom: 0px;margin-bottom: 0px\">Up to 12 amperes per microsecond at 240 kilowatts<\/strong> of current slew rate to emulate the rapid load transitions that challenge 800-volt power shelves and power racks.<\/li>\r\n<li><strong style=\"font-weight: 500;color: #000000;font-family: Manrope, sans-serif;padding-bottom: 0px;margin-bottom: 0px\">Up to 95% regenerative efficiency<\/strong> to return absorbed energy to the grid, helping reduce lab heat and cooling demand while easing power-infrastructure requirements for long-duration efficiency, burn-in, endurance and lifetime testing.<\/li>\r\n<li><strong style=\"font-weight: 500;color: #000000;font-family: Manrope, sans-serif;padding-bottom: 0px;margin-bottom: 0px\">Up to 1.92 megawatts of modular test capacity <\/strong>across up to eight racks and 64 loads, expanding in 30-kilowatt increments so teams can grow validation capacity as rack and infrastructure power requirements increase. Each rack delivers up to 240 kilowatts in a compact 0.6-square-meter footprint.<\/li>\r\n<\/ul>\r\n<p style=\"margin-bottom: 0.5em;font-size: 18px;line-height: 32px;font-weight: 400;font-family: Manrope, sans-serif;color: #000000;margin-top: 0px\">The EA-ELR 21000-80 4U HS is rated for up to 1,000 volts, 80 amperes and 30 kilowatts in 4U, giving teams the voltage headroom needed to evaluate 800-volt DC power architectures. Integrated waveform generation supports repeatable load profiles, while coordinated controls enable multiple loads to operate as one synchronized test system. The modular architecture also lets teams add capacity as requirements evolve and service individual modules without disrupting the entire system.<\/p>\r\n<p style=\"margin-bottom: 0.5em;font-size: 18px;line-height: 32px;font-weight: 400;font-family: Manrope, sans-serif;color: #000000;margin-top: 0px\">The EA-ELR 21000 is designed for power shelves and power racks supporting 800-volt DC distribution, as well as solid-state transformers that convert medium-voltage AC power for high-power DC infrastructure. It gives manufacturers a way to evaluate dynamic behavior, stability, conversion efficiency and long-term reliability before those systems are deployed in AI data centers.<\/p>\r\n<p style=\"margin-bottom: 0.5em;font-size: 18px;line-height: 32px;font-weight: 400;font-family: Manrope, sans-serif;color: #000000;margin-top: 0px\">\u00a0<\/p>\r\n<h3 style=\"clear: both;font-size: clamp(21px, 5vw, 32px);line-height: 1.2;font-family: Manrope, sans-serif;font-weight: 300;color: #002145;margin: 0px;padding-bottom: 30px\"><strong style=\"font-weight: bold;font-family: Manrope, sans-serif;padding-bottom: 0px;margin-bottom: 0px\">Coming this fall: high-dynamic regenerative test for the next power stage<\/strong><\/h3>\r\n<p style=\"margin-bottom: 0px;font-size: 18px;line-height: 32px;font-weight: 400;font-family: Manrope, sans-serif;color: #000000;margin-top: 0px;padding-bottom: 0px\">Later this fall, Tektronix will introduce the EA-ELR 20080-1000 4U HS, an 80-volt, 1,000-ampere regenerative electronic load module designed to help engineers validate the 48- to 54-volt rail that carries high current closer to AI compute. Part of Tektronix&#039;s ongoing innovation in high-power test, the module will help ensure engineers have the right tools for the next major conversion stage in the AI data center power path.<\/p>\r\n<\/div>\t\t<\/div>\n\t<\/div>\n<\/div>\r\n\t<div class=\"articles bg--offwhite automatic\">\r\n\t\t<div class=\"container\">\r\n\t\t\t<div class=\"articles__header\">\r\n\t\t\t\t\t\t\t\t\t<div class='heading-wrapper'><svg width=\"13\" height=\"13\" viewbox=\"0 0 13 13\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><circle cx=\"6.394\" cy=\"6.5\" r=\"6.394\" fill=\"#000\"\/><\/svg><h2>Related articles<\/h2><\/div>\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"\/en\/profiel\/cn-rood\/\" class=\"button button--outline\">view profile<\/a>\r\n\t\t\t\t\t\t\t<\/div>\r\n\t\t\t\t\t\t<div class=\"post-grid post-grid--no-padding\">\r\n\t\t\t\t\n<a class=\"single-item single-item__articles\" href=\"https:\/\/fhi.nl\/en\/news\/han-inox-roestvrijstalen-behuizingen-beschermen-tegen-corrosie-en-agressieve-stoffen\/\" data-id=\"32229\">\n\t<div class=\"single-item__articles-icon\">\n\t\t<svg width=\"103\" height=\"103\" viewbox=\"0 0 103 103\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\">\n<path fill-rule=\"evenodd\" clip-rule=\"evenodd\" d=\"M49.5 98.9587V82.3076C33.3844 81.2758 20.6328 67.878 20.6328 51.5019C20.6328 35.1258 33.3844 21.728 49.5 20.6962V4.04134C24.1941 5.08952 4 25.9365 4 51.5C4 77.0635 24.1941 97.9105 49.5 98.9587ZM53.5 78.2983V61.8096H76.3238C72.5238 70.9498 63.8222 77.5397 53.5 78.2983ZM49.5 78.298V61.8096H26.681C30.4804 70.9484 39.1799 77.5377 49.5 78.298ZM47.0728 57.8096H25.3773C24.8906 55.7865 24.6328 53.6743 24.6328 51.5019C24.6328 37.3358 35.5955 25.7301 49.5 24.7058V37.013H34.0466C33.2709 37.013 32.5653 37.4615 32.2359 38.1637C31.9065 38.8659 32.0128 39.6952 32.5086 40.2916L47.0728 57.8096ZM55.9249 57.8096H77.6274C78.1141 55.7865 78.3719 53.6743 78.3719 51.5019C78.3719 37.3342 67.4068 25.7275 53.5 24.7055V37.013H68.9511C69.7268 37.013 70.4324 37.4615 70.7618 38.1637C71.0912 38.8659 70.9849 39.6952 70.4891 40.2916L55.9249 57.8096ZM53.5 82.3079V98.9587C78.8059 97.9105 99 77.0635 99 51.5C99 25.9365 78.8059 5.08952 53.5 4.04134V20.6959C69.6178 21.7254 82.3719 35.1242 82.3719 51.5019C82.3719 67.8796 69.6178 81.2784 53.5 82.3079ZM0 51.5C0 23.7271 21.9843 1.08883 49.5 0.0381213V0H51.5H53.5V0.0381213C81.0157 1.08883 103 23.7271 103 51.5C103 79.9427 79.9427 103 51.5 103C23.0573 103 0 79.9427 0 51.5ZM38.3102 41.013H64.6875L51.4989 56.8765L38.3102 41.013Z\" fill=\"#2DD881\"\/>\n<\/svg>\n\t<\/div>\n\t<div class=\"single-item__articles-title\"><div class='heading-wrapper'><h3>Han-INOX\u00ae stainless steel housings protect against corrosion and aggressive substances<\/h3><\/div><\/div>\n\t<div class=\"single-item__articles-terms\">\n\t\t\n\t\t\n\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">Industrial Electronics<\/span>\n\t\t\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">Industrial automation<\/span>\n\t\t\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">Active components<\/span>\n\t\t\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">Members content<\/span>\n\t\t\t\t\t<\/div>\n\t<div class=\"single-item__articles-author-date-wrapper\">\n\t\t\t\t\t<div class=\"single-item__articles-author\">\n\t\t\t\tHARTING\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"single-item__articles-date\">\n\t\t\t\tDecember 5, 2023\t\t\t<\/div>\n\t\t\t<\/div>\n<\/a>\n\n<a class=\"single-item single-item__articles\" href=\"https:\/\/fhi.nl\/en\/news\/opleidingsoverzicht-laboratoriumopleidingen-habeo-najaar-2022\/\" data-id=\"35363\">\n\t<div class=\"single-item__articles-icon\">\n\t\t<svg width=\"82\" height=\"98\" viewbox=\"0 0 82 98\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\">\n<path fill-rule=\"evenodd\" clip-rule=\"evenodd\" d=\"M26.5586 7.96501C26.5586 6.61879 26.8909 5.49682 27.3233 4.77796C27.7792 4.02009 28.1318 4 28.1466 4H55.0564C55.0712 4 55.4238 4.02009 55.8796 4.77796C56.312 5.49682 56.6444 6.61879 56.6444 7.96501C56.6444 9.31122 56.312 10.4332 55.8796 11.1521C55.4238 11.9099 55.0712 11.93 55.0564 11.93H54.2487C53.8841 11.5449 53.3681 11.3047 52.796 11.3047H28.981C28.5233 11.3047 28.1015 11.4584 27.7644 11.7171C27.6381 11.602 27.4874 11.4248 27.3233 11.1521C26.8909 10.4332 26.5586 9.31122 26.5586 7.96501ZM26.981 15.7683C25.6024 15.3755 24.5619 14.3215 23.8956 13.2138C23.0294 11.7738 22.5586 9.91326 22.5586 7.96501C22.5586 6.01675 23.0294 4.15622 23.8956 2.71619C24.7383 1.31517 26.1797 0 28.1466 0H55.0564C57.0232 0 58.4646 1.31517 59.3073 2.71619C60.1735 4.15622 60.6444 6.01675 60.6444 7.96501C60.6444 9.91326 60.1735 11.7738 59.3073 13.2138C58.4646 14.6148 57.0232 15.93 55.0564 15.93H54.796V40.3243L80.5327 84.0062L80.5391 84.0172L80.5503 84.0368C84.0711 90.2609 79.5954 97.9997 72.4362 97.9997H9.34052C2.18152 97.9997 -2.29415 90.2608 1.22665 84.0368C1.23243 84.0265 1.23831 84.0163 1.24428 84.0062L26.981 40.3243V15.7683ZM30.981 15.93V35.792H39.161C40.2655 35.792 41.161 36.6874 41.161 37.792C41.161 38.8966 40.2655 39.792 39.161 39.792H30.981V40.8697C30.981 41.2268 30.8854 41.5773 30.7041 41.8849L21.3184 57.8149H60.4585L51.0728 41.8849C50.8916 41.5773 50.796 41.2268 50.796 40.8697V15.93H30.981ZM62.8152 61.8148C62.8065 61.8149 62.7978 61.8149 62.7891 61.8149H19.4727C19.3082 61.8149 19.1484 61.7951 18.9954 61.7577L4.70016 86.0205C2.69212 89.5942 5.27194 93.9997 9.34052 93.9997H72.4362C76.5051 93.9997 79.0848 89.5941 77.0768 86.0205L62.8152 61.8148Z\" fill=\"#FFDA56\"\/>\n<\/svg>\n\t<\/div>\n\t<div class=\"single-item__articles-title\"><div class='heading-wrapper'><h3>Overview of Habeo+ laboratory training courses Autumn 2022<\/h3><\/div><\/div>\n\t<div class=\"single-item__articles-terms\">\n\t\t\n\t\t\n\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">Laboratory Technology<\/span>\n\t\t\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">LabSafety<\/span>\n\t\t\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">General laboratory equipment<\/span>\n\t\t\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">General laboratory supplies<\/span>\n\t\t\t\t\t<\/div>\n\t<div class=\"single-item__articles-author-date-wrapper\">\n\t\t\t\t\t<div class=\"single-item__articles-author\">\n\t\t\t\tHabeo+\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"single-item__articles-date\">\n\t\t\t\tJuly 19, 2022\t\t\t<\/div>\n\t\t\t<\/div>\n<\/a>\n\n<a class=\"single-item single-item__articles\" href=\"https:\/\/fhi.nl\/en\/news\/inductive-solutions-for-the-energy-transition\/\" data-id=\"31327\">\n\t<div class=\"single-item__articles-icon\">\n\t\t<svg width=\"35\" height=\"35\" viewbox=\"0 0 35 35\" fill=\"none\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\">\n<mask id=\"mask0_1182_5532\" style=\"mask-type:luminance\" maskunits=\"userSpaceOnUse\" x=\"0\" y=\"0\" width=\"35\" height=\"35\">\n<path d=\"M0 0H35V35H0V0Z\" fill=\"white\"\/>\n<\/mask>\n<g mask=\"url(#mask0_1182_5532)\">\n<path d=\"M5.12695 9.22852H1.02539V31.9238H10.4299C12.2868 31.9238 14.0678 32.6615 15.3809 33.9746H19.6191C20.9322 32.6615 22.7132 31.9238 24.5701 31.9238H33.9746V11.2793H29.873\" stroke=\"#2A5CEE\" stroke-width=\"2\" stroke-miterlimit=\"10\"\/>\n<path d=\"M17.5 9.22852H18.1426C20.0088 7.89544 22.2237 7.17773 24.5615 7.17773H29.873V27.8223H24.5615C22.2237 27.8223 20.0088 28.54 18.1426 29.873H16.8574C14.9912 28.54 12.7763 27.8223 10.4385 27.8223H5.12695V5.12695H9.22852\" stroke=\"#2A5CEE\" stroke-width=\"2\" stroke-miterlimit=\"10\"\/>\n<path d=\"M9.22852 1.02539V21.6699C13.759 21.6699 17.5 25.3425 17.5 29.873V9.22852C17.5 4.698 13.759 1.02539 9.22852 1.02539Z\" stroke=\"#2A5CEE\" stroke-width=\"2\" stroke-miterlimit=\"10\"\/>\n<\/g>\n<\/svg>\n\t<\/div>\n\t<div class=\"single-item__articles-title\"><div class='heading-wrapper'><h3>Inductive solutions for the energy transition<\/h3><\/div><\/div>\n\t<div class=\"single-item__articles-terms\">\n\t\t\n\t\t\n\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">Design Automation &amp; Embedded Systems Event<\/span>\n\t\t\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">Industrial Electronics<\/span>\n\t\t\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">Active components<\/span>\n\t\t\t\t\t\t\t\t<span class=\"button button--outline single-item__articles-term--branche single-item__articles-term\">Members content<\/span>\n\t\t\t\t\t<\/div>\n\t<div class=\"single-item__articles-author-date-wrapper\">\n\t\t\t\t\t<div class=\"single-item__articles-author\">\n\t\t\t\tAlcom Electronics BV\t\t\t<\/div>\n\t\t\t\t\t\t\t<div class=\"single-item__articles-date\">\n\t\t\t\tMay 27, 2024\t\t\t<\/div>\n\t\t\t<\/div>\n<\/a>\n\t\t\t<\/div>\r\n\t\t<\/div>\r\n\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Tektronix has announced the EA-ELR 21000 Dynamic Test System, an auto-ranging, high-dynamic electronic load test system built on a fully regenerative architecture for validating the \u00b1400-volt and 800-volt DC power architectures emerging in AI data centers. Rather than dissipating absorbed test energy as heat, the system returns it to the grid with up to 95% regenerative efficiency, helping manufacturers conduct sustained high-power validation with less demand on lab power and cooling infrastructure.<\/p>","protected":false},"featured_media":90690,"template":"","branches":[13],"events":[364,8],"secretariat":[],"categories":[17,57,22],"themes_tax":[541,510,523],"content_types":[514],"class_list":["post-90689","news","type-news","status-publish","has-post-thumbnail","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.6 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Tektronix introduces fully regenerative dynamic test system for 800-volt AI data center power<\/title>\n<meta name=\"description\" content=\"EA-ELR 21000 system pairs a new 1,000-volt electronic load with modular capacity from 30 kilowatts to 1.92 megawatts\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/cnrood.com\/news-articles\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Tektronix introduces fully regenerative dynamic test system for 800-volt AI data center power\" \/>\n<meta property=\"og:description\" content=\"EA-ELR 21000 system pairs a new 1,000-volt electronic load with modular capacity from 30 kilowatts to 1.92 megawatts\" \/>\n<meta property=\"og:url\" content=\"https:\/\/cnrood.com\/news-articles\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\/\" \/>\n<meta property=\"og:site_name\" content=\"FHI, Federatie van technologiebranches\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-03T15:54:24+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/fhi.nl\/app\/uploads\/2026\/11\/datacenter-ea.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1103\" \/>\n\t<meta property=\"og:image:height\" content=\"697\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/fhi.nl\\\/nieuws\\\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\\\/\",\"url\":\"https:\\\/\\\/cnrood.com\\\/news-articles\\\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\\\/\",\"name\":\"Tektronix introduces fully regenerative dynamic test system for 800-volt AI data center power\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/fhi.nl\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/cnrood.com\\\/news-articles\\\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/cnrood.com\\\/news-articles\\\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/fhi.nl\\\/app\\\/uploads\\\/2026\\\/11\\\/datacenter-ea.jpg\",\"datePublished\":\"2026-11-03T15:45:00+00:00\",\"dateModified\":\"2026-11-03T15:54:24+00:00\",\"description\":\"EA-ELR 21000 system pairs a new 1,000-volt electronic load with modular capacity from 30 kilowatts to 1.92 megawatts\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/cnrood.com\\\/news-articles\\\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/cnrood.com\\\/news-articles\\\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/cnrood.com\\\/news-articles\\\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\\\/#primaryimage\",\"url\":\"https:\\\/\\\/fhi.nl\\\/app\\\/uploads\\\/2026\\\/11\\\/datacenter-ea.jpg\",\"contentUrl\":\"https:\\\/\\\/fhi.nl\\\/app\\\/uploads\\\/2026\\\/11\\\/datacenter-ea.jpg\",\"width\":1103,\"height\":697},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/cnrood.com\\\/news-articles\\\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/fhi.nl\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Nieuws\",\"item\":\"https:\\\/\\\/fhi.nl\\\/nieuws\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Tektronix introduces fully regenerative dynamic test system for 800-volt AI data center power\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/fhi.nl\\\/#website\",\"url\":\"https:\\\/\\\/fhi.nl\\\/\",\"name\":\"FHI, federatie van technologiebranches\",\"description\":\"Nederlandse branchevereniging voor technologiebranches\",\"publisher\":{\"@id\":\"https:\\\/\\\/fhi.nl\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/fhi.nl\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/fhi.nl\\\/#organization\",\"name\":\"FHI, federatie van technologiebranches\",\"url\":\"https:\\\/\\\/fhi.nl\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/fhi.nl\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/fhi.nl\\\/app\\\/uploads\\\/2024\\\/06\\\/3-e1722349014385.png\",\"contentUrl\":\"https:\\\/\\\/fhi.nl\\\/app\\\/uploads\\\/2024\\\/06\\\/3-e1722349014385.png\",\"width\":732,\"height\":136,\"caption\":\"FHI, federatie van technologiebranches\"},\"image\":{\"@id\":\"https:\\\/\\\/fhi.nl\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/fhi-federation-of-technology-branches\",\"https:\\\/\\\/www.instagram.com\\\/fhi_nl\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Tektronix introduces fully regenerative dynamic test system for 800-volt AI data center power","description":"EA-ELR 21000 system pairs a new 1,000-volt electronic load with modular capacity from 30 kilowatts to 1.92 megawatts","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/cnrood.com\/news-articles\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\/","og_locale":"en_GB","og_type":"article","og_title":"Tektronix introduces fully regenerative dynamic test system for 800-volt AI data center power","og_description":"EA-ELR 21000 system pairs a new 1,000-volt electronic load with modular capacity from 30 kilowatts to 1.92 megawatts","og_url":"https:\/\/cnrood.com\/news-articles\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\/","og_site_name":"FHI, Federatie van technologiebranches","article_modified_time":"2026-11-03T15:54:24+00:00","og_image":[{"width":1103,"height":697,"url":"https:\/\/fhi.nl\/app\/uploads\/2026\/11\/datacenter-ea.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/fhi.nl\/nieuws\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\/","url":"https:\/\/cnrood.com\/news-articles\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\/","name":"Tektronix introduces fully regenerative dynamic test system for 800-volt AI data center power","isPartOf":{"@id":"https:\/\/fhi.nl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/cnrood.com\/news-articles\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\/#primaryimage"},"image":{"@id":"https:\/\/cnrood.com\/news-articles\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\/#primaryimage"},"thumbnailUrl":"https:\/\/fhi.nl\/app\/uploads\/2026\/11\/datacenter-ea.jpg","datePublished":"2026-11-03T15:45:00+00:00","dateModified":"2026-11-03T15:54:24+00:00","description":"EA-ELR 21000 system pairs a new 1,000-volt electronic load with modular capacity from 30 kilowatts to 1.92 megawatts","breadcrumb":{"@id":"https:\/\/cnrood.com\/news-articles\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/cnrood.com\/news-articles\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/cnrood.com\/news-articles\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\/#primaryimage","url":"https:\/\/fhi.nl\/app\/uploads\/2026\/11\/datacenter-ea.jpg","contentUrl":"https:\/\/fhi.nl\/app\/uploads\/2026\/11\/datacenter-ea.jpg","width":1103,"height":697},{"@type":"BreadcrumbList","@id":"https:\/\/cnrood.com\/news-articles\/tektronix-introduces-fully-regenerative-dynamic-test-system-for-800-volt-ai-data-center-power\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/fhi.nl\/"},{"@type":"ListItem","position":2,"name":"Nieuws","item":"https:\/\/fhi.nl\/nieuws\/"},{"@type":"ListItem","position":3,"name":"Tektronix introduces fully regenerative dynamic test system for 800-volt AI data center power"}]},{"@type":"WebSite","@id":"https:\/\/fhi.nl\/#website","url":"https:\/\/fhi.nl\/","name":"FHI, federation of technology industries","description":"Dutch trade association for technology industries","publisher":{"@id":"https:\/\/fhi.nl\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/fhi.nl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Organization","@id":"https:\/\/fhi.nl\/#organization","name":"FHI, federation of technology industries","url":"https:\/\/fhi.nl\/","logo":{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/fhi.nl\/#\/schema\/logo\/image\/","url":"https:\/\/fhi.nl\/app\/uploads\/2024\/06\/3-e1722349014385.png","contentUrl":"https:\/\/fhi.nl\/app\/uploads\/2024\/06\/3-e1722349014385.png","width":732,"height":136,"caption":"FHI, federatie van technologiebranches"},"image":{"@id":"https:\/\/fhi.nl\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/fhi-federation-of-technology-branches","https:\/\/www.instagram.com\/fhi_nl\/"]}]}},"_links":{"self":[{"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/news\/90689","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/news"}],"about":[{"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/types\/news"}],"version-history":[{"count":0,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/news\/90689\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/media\/90690"}],"wp:attachment":[{"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/media?parent=90689"}],"wp:term":[{"taxonomy":"branches","embeddable":true,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/branches?post=90689"},{"taxonomy":"events","embeddable":true,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/events?post=90689"},{"taxonomy":"secretariat","embeddable":true,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/secretariat?post=90689"},{"taxonomy":"categories","embeddable":true,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/categories?post=90689"},{"taxonomy":"themes","embeddable":true,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/themes_tax?post=90689"},{"taxonomy":"content_types","embeddable":true,"href":"https:\/\/fhi.nl\/en\/wp-json\/wp\/v2\/content_types?post=90689"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}