In addition to the CIM1 version, a CIM2 and CIM3 variant is also available. This makes it possible to cover the 18 most common timer functions with just 3 types of time relays. Per type you can then choose between a relay, triac or mosfett output. All CIM time relays can be set in 7 time ranges, varying from a minimum of 50 ms to a maximum of 60 hours. The modules are suitable for a supply voltage of 16.8…250VAC/DC. In addition, the modules are equipped with an LED indication and a switch for manual operation.
The most important specifications:
- Wide voltage range: 16.8…250VAC/DC;
- Time adjustable from 50 ms to 60 hours;
- CIM1x; 9 Time functions: E, A, K, N, B, B1, W, stair light switching function S and LS;
- CIM2x; 7 time functions E, B2, H, A, L, M, and G;
- CIM3x; 6 time functions: F, Q, G, I, P and H;
- Ambient temperature during operation: -40…+60ºC (railway version up to +70ºC)
- Versions available with Railway Approval according to EN5015
PDF: CIM
If you would like more information after reading this article, please feel free to contact our Sales department. Tel: 0346 – 594 555.